Countermeasure when the machine stopped
196
Chapter 9
QS07
292
Material feed error occurred at zigzag cording
device.
Check the material. Check the sensor card,
harness etc. of zigzag cording device.
293 Under thread breakage is detected.
Check under thread.
294
Absence of sequin material is detected (Sequin
device III only).
Check the material.
2B1 Network does not work normally.
Check connecting status of cable, setting
status of device such as personal computer.
2B3 Data exists in an end code.
Correct design data.
2B4 Function code error
2B5 Sequin data error
2B7 Data set is not completed.
Set data.
2BA Memory capacity exceeded
Delete unnecessary design(s) registered in the
memory.
2BB
Available range to perform frame back was
exceeded.
Do not perform frame back any more.
2BC
No design is registered in the memory at all.
Register designs in the memory.
The delete of design in process of embroidery
was attempted.
To perform memory delete of design in process
of embroidery, perform data input of other data
or perform data input of the same design again.
Data edit was attempted during embroidery.
Do not perform data edit during embroidery.
2BE
Start and End codes are not set as a one pair in
satin conversion, sequin, boring and low speed
code.
Set again so that start and end codes become
as a pair.
2C1
Machine was started during setting of data edit or
needle bar selection.
Start the machine after ending the setting.
2C2 Setting for option is incorrect.
Set correctly.
2C6
The machine was operated during working of
bobbin changer.
Do not operate the machine during working of
bobbin changer.
2C7 Wrong password is input.
After pressing E key, input the correct
password.
2C8 Sleep mode key was pressed during trace.
Press the E key.
2C9
Time was changed during setting of Password
(Time-based Limit).
Press the E key.
2CA The power is not turned "OFF/ON".
Turn "OFF/ON" the power.
2CE Stop by safety device
After removing the obstacle, press E key, then
press the start switch.
2E2
Air pressure of the regulator has become lower
than the rated value.
Check the air compressor. Check the origin of
air supply.
2E3 Power supply failed during operation.
Perform power resume operation after turning
ON the power.
B01 Abnormality occurred in reading/writing.
Copy design to a new USB memory and use it.
No.
Stop Factor
How to restore
Summary of Contents for TEMX-C Series
Page 13: ...To search from the menu key ...
Page 25: ...Inspection before starting work 12 Chapter 1 ...
Page 39: ...How to use each part 26 Chapter 2 ...
Page 40: ... E 1 2 3 4 5 6 7 8 9 10 11 27 PT10 Chapter 3 Screen 1 Screen display 28 2 Message display 31 ...
Page 147: ...Other functions that must be remembered 134 Chapter 5 ...
Page 171: ...To move the frame to the position registered 158 Chapter 6 ...