Other functions that must be remembered
132
Chapter 5
QS07
11-6.
To release fixing of main shaft motor (weak brake)
It is the setting to release the fixing of the main shaft motor temporarily while the main shaft stops.
This function is used for the maintenance of the machine mainly.
11-6-1.
Explanation on the screen
[a]
Fixing of main shaft motor
YES: To fix the main shaft motor while the main shaft stops (usual setting)
NO: Not to fix the main shaft motor while the main shaft stops
Even if "NO" is selected, it will be switched to "YES" after starting the machine.
Always NO: Not to fix the main shaft motor always while the main shaft stops
"Always NO" will be displayed in single head machine only.
[b]
Current main shaft angle
When you desire to check the main shaft angle, set the value of above [a] to "NO" or "Always
NO", and then turn the main shaft.
When left code is displayed, follow the procedure below.
1.
2.
3.
F3
2 Weak Brake
Set
YES
100
YES / NO/ Always NO
[a]
Fixing of main shaft motor
[b]
Current main shaft angle
[° ]
***
Set the value of [a] to "NO".
Turn the main shaft slowly until the lamp in the figure below (indicated by an
arrow) starts blinking.
AS FB
After the screen is switched (press E key) and the original screen is returned,
"100" (fixed position) will be displayed.
100
Summary of Contents for TEMX-C Series
Page 13: ...To search from the menu key ...
Page 25: ...Inspection before starting work 12 Chapter 1 ...
Page 39: ...How to use each part 26 Chapter 2 ...
Page 40: ... E 1 2 3 4 5 6 7 8 9 10 11 27 PT10 Chapter 3 Screen 1 Screen display 28 2 Message display 31 ...
Page 147: ...Other functions that must be remembered 134 Chapter 5 ...
Page 171: ...To move the frame to the position registered 158 Chapter 6 ...