4
Page
Model
140 Indoor
140 Outdoor
Natural Gas Input
(Operating Range)
BTU/h
Min.: 15,000
Max.: 120,000
Propane Input
(Operating Range)
BTU/h
Min.: 15,000
Max.: 120,000
Gas Connection
1/2" NPT
Water Connection
3/4" NPT
Water Pressure*
psi
(MPa)
15 - 150 (0.1 - 1.0)
Natural gas
Inlet Pressure
inch W.C.
(kPa)
Min. 4.0 (1.0)
Max. 10.5 (2.6)
Propane
Inlet Pressure
inch W.C.
(kPa)
Min. 8.0 (2.0)
Max. 14.0 (3.5)
Weight
lbs. (kg)
50 (22.5)
50 (22.5)
Dimension
inch
H 21-3/4 x W 14 x D 9-1/4
H 552 x W 352 x D 236
mm
Ignition
Electric Ignition
Electric
Supply
VAC / Hz
120 / 60
Consump
tion
Operation
W / A
53.9 / 0.7
Standby
W / A
3.2 / 0.05
Freeze-
Protection
W / A
223.9 / 1.94
Water heater category**
Category IV
N/A
SPECIFICATIONS
*40 psi or above is recommended for maximum flow.
**Water heater Category —
water heaters of other than direct vent type, for outdoor installation, are divided into four
categories based on static pressure produced in the vent and flue loss.
Category I -
a water heater that operates with a non-positive vent static pressure and with a vent gas temperature
that avoids excessive condensate production in the vent.
Category II -
a water heater that operates with a non-positive vent static pressure and with a vent gas temperature
that may cause excessive condensate production in the vent.
Category III -
a water heater that operates with a positive vent static pressure and with a vent gas temperature that
avoids excessive condensate production in the vent.
Category IV -
a water heater that operates with a positive vent static pressure and with a vent gas temperature that
may cause excessive condensate production in the vent.
NOTE:
• Check the rating plate to ensure that this product matches your specifications.
•
The manufacturer reserves the right to discontinue, or change at any time, specifications or designs
without notice and without incurring obligation.
Installation Manual