On-Demand Water Heater Installation Manual and Owner’s Guide
Operation
Controllers
Built-in controller
Remote controller
1.
Turn on the 120 VAC power supply to the unit.
2.
Press the
"ON/OFF"
button on the controller in order to
turn the controller on.
3.
When ON, the STAND BY LED is lit.
4.
It shows the set temperature of output water on its
display as shown in the picture on the right. (EX.: 120°F)
5.
Press the
"HOT"
button or the
"COLD"
button to set the
temperature setting of the unit.
WARNING
Temperatures above 125°F (52°C) can
cause severe burns or death from
scalding. Children, disabled and the
elderly are at high risk of being injured.
Increasing temperature from 120°F (50°C) to 125°F (52°C) :
1. The water heater must be in Stand By to increase the
temperature.
2. Press the "HOT" button to set 120°F (50°C).
3. Press and hold the "INFO" button and the "HOT"
button for at least 3 seconds. The remote will emit a
beep and change to 125°F (52°C).
4. Press the "HOT" button to set up to 140°F (60°C).
(EX.: 120°F)
-Set outlet water temperature-
Temperature Table of Controller
The following table lists the available temperature setting.
The factory temperature setting is 120°F (50°C)
°F
100 105 110 115 120 125 130 135 140
°C
38
40
43
45
50
52
55
57
60
OPERATION
Controller settings