- 7 -
GENERAL
1.
The manifold gas pressure is preset at the factory.
It is computer controlled and should
not need adjustment.
2.
Maintain proper space for servicing.
Install the unit so that it can be connected or
removed easily. Refer to p. 9 and p. 10 for proper clearances.
3.
The electrical connection requires a means of disconnection, to terminate power to the
water heater for servicing and safety purposes.
4.
If you will be installing the unit in a contaminated area with a high level of dust, sand,
flour, aerosols or other contaminants/chemicals, they can become airborne and enter
and build up within the fan and burner causing damage to the unit. In those
environments (e.g. residential or commercial laundry facilities, hair salons, pet salons,
chemical plants etc.), please purchase the optional direct-vent conversion kit and
convert the water heater to a sealed combustion unit. Direct venting allows the water
heater to draw fresh intake air from the outside.
The warranty will not cover damage
caused to the unit due to installation in a contaminated environment that has not been
converted using the direct-vent conversion kit.
5.
Particles from flour, aerosols, and other contaminants may clog the air vent or reduce
the functions of the rotating fan and cause improper burning of the gas. Regularly ensure
that the area around the unit is dust- or debris-free; regular maintenance is
recommended for these types of environment.
6.
Do not install the unit where the exhaust vent is pointing into any opening in a building or
where the noise may disturb your neighbors. Make sure the vent termination meets the
required distance by local code from any doorway or opening to prevent exhaust from
entering a building (refer to p. 15).
INCLUDED ACCESSORIES
Check that these items below are included with the water heater.
Items
Manual
Communication Cable
Qty: 1
Qty: 1