10
Page
The pipe cover protects
the plumbing pipes to
the water heater. It is
fixed to the bottom of
the water heater, so it
hides the plumbing and
improves the appearance
of the installation.
3. Recess box:
It allows for “clean” installations. The water heater fits inside
the recess box, which hides and protects the whole water heater and plumbing.
The recess box will fit between most wall studs.
1. 4” Backflow preventer and Female-female adaptor
9007996005
9008146004
100266729
100266730
It prevents the backflow of air through the exhaust vent. This
helps prevent harmful exhaust gases from entering the home, as
well as helping to prevent the unit from freezing in areas where
cold air can be blown or drawn into the exhaust system.
Install this adaptor in accordance with the installation instructions
that are packaged with the adaptor and any applicable codes.
9007996005 (4” Backflow preventer and F-F adaptor):
Must be installed in the vertical position.
9008146005 (4" Universal Appliance Adaptor, F-F adaptor, backflow preventer, condensate drain trap): Must be installed in the
vertical position on the heater's flue collar.
4. Sidewall vent terminator (Hood) and Wall thimble:
Sidewall vent termination (Round) and Wall thimble:
This component is used to terminate direct-vent (sealed
combustion) systems with indoor models that require a
3 in. intake and a 4 in. exhaust. This concentric termination provides the convenience
of only having to make one penetration through a sidewall instead of two separate
penetrations for the intake and exhaust piping. The termination includes a bird
screen, restricting small animals, pests, and foreign objects from entering into the
vent system. This sidewall termination is available in two different sizes to cover a
wide range of wall thicknesses. For different wall thicknesses,there are two ranges
of lengths available. (Refer to the venting manufacturer's specifications for details.)
Installation
Installation Manual
Covering wall thicknesses
Part#
Terminator Hood
9007999005
Wall Thimble 4 - 7 in.
9008345005
Wall Thimble 5 - 10 in.
9008346005
Termi Thimble 4 - 7 in.
9008004005
Termi Thimble 5 - 10 in.
9008005005
Covering wall thicknesses
Part#
Termination
9008899005
Wall Thimble
9008898005
Termi Thimble
9008900005
2. Pipe cover: 9007670005 (TK-PC01)
Covering wall thicknesses
Part#
5.0 – 10.0 in.
9008147005
12.0 – 18.0 in.
9008148005
5. Direct-vent concentric termination:
The terminator hood and wall thimble can be used to vent through a wall. These terminations are special stainless steel
vents for gas appliances and are listed as Category II, III and IV. For different wall thicknesses, there are two ranges of lengths
available. (Refer to the NovaVent brochure for details.) Install these vent terminations in accordance with their installation
instructions and any applicable local codes.
Refer to p. 21 regarding the DIP switch settings for the termination.
Wall Thimble
Terminator Hood
6. Remote controller:
9009069005 (TM-RE42)
9008900005 (Termi Thimble)
Outdoor recess box
for retrofic applications-
no flange
Outdoor recess box
for new construction
applications-with flange
9008899005
(Termination)
9008898005
(Wall Thimble)