Combustion Air Supply Options
Gable vent
to outdoors
Install above
insulation
Outlet air to
attic 1 in
2
per
4,000 btu/h
Inlet air from
the crawl space
Open foundation vent
Confined
Space
Alternate
Air Inlet
1 in
2
per
4,000 btu/h
Figure 1 -
Direct to outdoors openings
Figure 3 - Vertical
duct openings
Outlet air to
attic 1 in
2
per
4,000 btu/h
Inlet air duct
1 in
2
per
4,000 btu/h
Confined
Space
12” maximum
Gable vent
to outdoors
Install above
insulation
Figure 5 -
SIngle opening
Confined
Space
1 in
2
per
3,000 btu/h
Alternative
Opening
Location
Figure 6 -
Two permanent openings
Two permanent
Openings
1 in
2
per
1,000 btu/h
12” maximum
12” maximum
Confined
Space
Figure 4 -
Horizontal duct openings
1 in
2
per
2,000 btu/h
Confined
Space
Outlet
Inlet
Outdoor
Air Ducts
1 in
2
per
2,000 btu/h
Figure 2 -
Direct to outdoors openings
Two permanent openings
Two permanent
Openings
1 in
2
per
4,000 btu/h
12” maximum
12” maximum
Confined
Space