19
Page
-Vent length and No. of Elbows-
This is a Category III appliance and must be vented accordingly. The vent system must be sealed airtight.
All seams and joints
without gaskets
must be sealed with high heat resistant silicone sealant or UL listed
aluminum adhesive tape having a minimum temperature rating of 350 °F (177 °C). For best results, a vent
system should be as short and straight as possible.
•
This water heater is a Category III appliance and must be vented accordingly with any 4 in. (102
mm) vent approved for use with Category III or Special BH type gas vent.
•
Follow the vent pipe manufacturer’s instructions when installing the vent pipe.
•
Do not common vent this appliance with any other vented appliance.
(Do not terminate vent
into a chimney. If the vent must go through the chimney, the vent must run all the way through
the chimney with Category III approved or Special BH vent pipe.)
•
When the horizontal vent run exceeds 5 ft. (1.5 m), support the vent run at 3 ft. (0.9 m) intervals
with overhead hangers.
•
The maximum length of exhaust vent piping must not exceed
60 ft. (18.3 m)
.* Deduct 5 ft.
(1.5 m) for each 90° elbow used in the venting system. Do not use more than
6 elbows
. A 45°
elbow is equivalent to 2.5 ft. of vent length.
*If vent termination kit
9008900005
is used in the installation, the maximun length of
exhaust
vent
pipe must not exceed
55 ft. (16.8 m)
, and the vent run must not exceed 5 elbows. Vent termination kit
9008900005 also has specific DIP switch settings. Refer to p. 22.
Vent type
Diameter
Max. No. of Elbows Max. Vertical and Horizontal (Total) Vent Length
Intake**
3 in. (76 mm)
6**
60 ft. (18.3 m )*
Exhaust
4 in. (102 mm)
5
55 ft. (16.8 m )*
*For each 90° elbow added, deduct 5 ft. (1.5m) from max. vent length.
**For Intake vent, refer to the above table of the installation of 6 elbows and 60 ft.
Vent type
Diameter
Max. No. of Elbows Max. Vertical and Horizontal (Total) Vent Length
Intake
3 in. (76 mm)
6
60 ft. (18.3 m )*
Exhaust
4 in. (102 mm)
6
60 ft. (18.3 m )*
*For each 90° elbow added, deduct 5 ft. (1.5m) from max. vent length.
No. of Elbows
Max. Vertical or Horizontal
Vent Length
No. of Elbows
Max. Vertical or Horizontal
Vent Length
0
60 ft. (18.3m)
4
40 ft. (12.2 m)
1
55 ft. (16.8 m)
5
35 ft. (10.7 m)
2
50 ft. (15.2 m)
6
30 ft. (9.1 m)
3
45 ft. (13.7 m)
Excludes elbow termination, rain caps, or the 4 in. (102 mm) Concentric termination.
No. of Elbows
Max. Vertical or Horizontal
Vent Length
No. of Elbows
Max. Vertical or Horizontal
Vent Length
0
55 ft. (16.8 m)
3
40 ft. (12.2 m)
1
50 ft. (15.2 m)
4
35 ft. (10.7 m)
2
45 ft. (13.7 m)
5
30 ft. (9.1 m)
Excludes sidewall termination.
Installation
Installation Manual
Standard Vent Terminations
(See the next table for vent termination 9008900005.)
Installation with vent termination kit 9008900005
Summary of Contents for AT-KJr3U-IN
Page 63: ...63 Page This page is intentionally left blank...
Page 64: ...1W1101 100269776...