Pressure relief Valve
CAUTION: The pipe heaters are located on the MOBIUS Water Heater only. Any hot or
cold water pipes located outside of the unit will not be protected. Properly protect and
insulate these pipes from freezing.
Electrical Connections
WARNING:
The heater must be electrically grounded. Follow the requirements of the local
authority having jurisdiction. In the absence of such requirements, follow the latest edition of
the National Electrical Code ANSI/NFPA 70.
Do not rely on the gas or water piping to ground the metal parts of the water heater, because
plastic pipe or dielectric unions may isolate the water heater electrically. Service and
maintenance personnel who work on or around the water heater may be standing on wet
floors, and could be electrocuted by an un-grounded water heater.
CAUTION:
Label all wires prior to disconnection when servicing controls. Wiring error can
cause improper and dangerous operation. Verify proper operation after servicing.
The MOBIUS water heater requires an electrical power supply of 120 VAC, 60 Hz, and it
must be properly grounded to function.
•
A means for switching off the 120 VAC power supply must be provided.
•
Wire the heater exactly as shown in the wiring diagram.
•
A green screw is provided in the junction box for the grounding connection.
Refer to the wiring diagram. There is a copy of the wiring diagram located on the inside
panel of the appliance.