Cleaning the Heat Exchanger
If the heat exchanger must be cleaned, follow this procedure.
1. Shut off all power to the water heater.
2. Use re-circulation method.
3. Wear Gloves when handling de-scaling solution.
4. Always ware EYE PROTECTION.
5. All equipment being de-scaled should be properly vented to prevent gas pressure
build-up during the cleaning operation.
6. Clean out any debris, which has fallen to the coldwater inlet filter.
MOBIUS Water Heater Troubleshooting:
The MOBIUS Water Heater Model T-M1 has a built in self-diagnostic computer mode for
safety and convenience in case of necessary maintenance service.
On the T-M1 computer board, a numeric error code will
appear when the MOBIUS water heater has a problem. This
error code will identify the symptoms of the problem and
indicate what service is necessary.
The T-M1 consists of five main systems. These are the
temperature control, the gas control, the water control, the
burner control, and the main computer control systems.
Trouble Shooting Flow chart:
The MOBIUS water heater is one of the most trouble free water heaters there are.
However, if there is trouble, use the error code on the computer to follow this trouble shooting
flow chart.
Error N0.
Component
031,141,711,741,
751
Main Computer Control
701
Temperature Control (Setting Temp.
+ over 50
°
F)
111, 121
Burner Flame
311, 321,331
Temperature control
391,611,721,991
Burner control
501 Gas
control
651, 661,541
Water control
101 Combustible
Air
211 Vent
pipe
Summary of Contents for MOBIUS