<Water Valves>
Valve A
Water Outlet Valve (Two way valve)
Valve B
Bypass Flow Adjustment Valve
Valve C
Flow Adjustment Valve
<Gas Valve>
Valve D
Solenoid Valve 1
Valve E
Solenoid Valve 2
Valve F
Solenoid Valve 3
Valve G
Proportional Valve
Valve H
Gas Inlet Valve (Main Valve)
Error
Symptom Error
Symptom
Error
Symptom
31
Wrong Gas Type
331
Mixing Thermistor Fail
701
Mixing Thermistor Abnormality
101
Insufficient Gas Supply
391
Thermocouple Abnormality
711
Gas Solenoid Valve Abnormality
111
Ignition Failure
510
Main Gas Valve Abnormality
721
Computer Pre-post Check Problem
121
Flame Loss
541
Two-Way Valve Abnormality
741
Main Remote Control Problem
141
Hi-Limit Switch
611
Fan Motor Abnormality
751
Temperature Remote Control Problem
311
Output Thermistor Fail
661
Bypass Valve Abnormality
761
Multi-system
Controller Problem
321
Inlet Thermistor Fail
651
Flow Adjust. Valve Abnormality
991
Abnormal Burning
211 Vent
pipe
Hi-limit switch works
(>208F)
Circuit board for Valve D
failure
Abnormal high water
temperature
⑥
Open Short:
Output Temp. Thermister
Open Short:
Mixing Temp. Thermister
Open Short:
Inlet Temp. Thermister
Thermo fuse cut off
(>360F)
Flame detector
Display: running off
Summary of Contents for MOBIUS