Installation
16
│
Page
‐
Additional
clearances
‐
Please
follow
all
local
and
national
codes
in
regards
to
proper
termination
clearances.
In
the
absence
of
such
codes,
the
following
clearances
can
be
used
as
guidelines.
Local
codes
supersede
these
guidelines.
For
sidewall
terminations
Exhaust
termination
1ft.
1ft.
2ft.
Inside
corner
For
multiple
sidewall
exhaust
terminations
(e.g.
multi
‐
unit
systems),
an
exhaust
termination
must
be
at
least
1
ft.
away
from
another
exhaust
termination.
An
exhaust
termination
must
also
be
at
least
2
ft.
away
from
an
inside
corner
(if
the
adjacent
wall
is
less
than
2
ft.
of
length,
the
minimum
required
distance
away
from
the
inside
corner
will
be
equal
to
the
length
of
that
adjacent
wall).
For
direct
‐
vent
sidewall
terminations
that
use
two
separate
penetrations
for
the
intake
and
exhaust,
distance
the
intake
and
exhaust
terminations
at
least
3
ft.
away
from
each
other,
no
matter
the
orientation.
For
multiple
‐
unit,
direct
‐
vent
sidewall
terminations
that
combine
the
intake
and
exhaust
into
a
single
penetration,
space
each
direct
‐
vent
termination
at
least
1
ft.
away
from
each
other,
no
matter
the
orientation.
A
direct
‐
vent
termination
must
also
be
at
least
2
ft.
away
from
an
inside
corner
(if
the
adjacent
wall
is
less
than
2
ft.
of
length,
the
minimum
required
distance
away
from
the
inside
corner
will
be
equal
to
the
length
of
that
adjacent
wall).
For
multiple
‐
unit
rooftop
terminations
(whether
for
standard
indoor
or
direct
‐
vent
installations)
space
all
exhaust
and
intake
terminations
in
accordance
with
local
codes.
An
exhaust
termination
must
be
spaced
from
a
wall
or
surface
in
accordance
with
local
codes
as
well.
In
the
absence
of
such
a
code,
an
exhaust
termination
must
be
a
horizontal
distance
of
at
least
2
ft.
away
from
a
wall
or
surface.
A:
in
accordance
with
local
codes
For
rooftop
terminations
Air
intake
Exhaust termination
A
A
A
A
A
2ft.
Air
intake
Exhaust
termination
Exhaust
and/or
direct
‐
vent
sidewall
terminations
should
be
at
least
2
ft.
away
from
an
opposite
surface/wall.
Do
not
place
the
termination
directly
in
front
of
an
opening
into
a
building.
2ft.
Exhaust
termination
Air
supply
inlet
3ft.
3ft.
3ft.
Direct
vent
termination
1ft.
1ft.
Inside
corner
2ft.