Contents
2
│
Page
CONTENTS
SPECIFICATIONS
T
‐
H2
‐
DV
and
T
‐
H2
‐
OS
Natural
Gas
Input
(Operating
Range)
Min:
13,000
Btu/h
Max:
199,000
Btu/h
LPG
Input
(Operating
Range)
Min:
13,000
Btu/h
Max:
199,000
Btu/h
Gas
Connection
¾”
NPT
Water
Connections
¾”
NPT
Condensate
Drain
Port
Connection
½
”
NPT
Water
Pressure
15
‐
150
psi*
Natural
Gas
Pressure
Inlet
Min.
5.0”
WC
Max.
10.5”
WC
LP
Gas
Pressure
Inlet
Min.
8.0”
WC
Max.
14.0”
WC
Manifold
Pressure
of
the
T
‐
H2
‐
DV
Natural:
3.2”
WC
Propane:
5.5”
WC
Manifold
Pressure
of
the
T
‐
H2
‐
OS
Natural:
2.7”
WC
Propane:
4.6”
WC
Weight
73
lbs.
(T
‐
H2
‐
DV)
70
lbs.
(T
‐
H2
‐
OS)
Dimensions
H25.6”
x
W18.5”
x
D12.4”
Ignition
Electric
Ignition
Electric
Supply
120VAC
(60Hz)
Consumption
Operation
of
the
T
‐
H2
‐
DV
152
W
(1.27A)
Operation
of
the
T
‐
H2
‐
OS
102W
(0.85A)
Standby
8.2
W
(0.07A)
Freeze
‐
Protection
207
W
(1.73A)
SPECIFICATIONS………………………………...
INTRODUCTION……………………………….…
SAFETY
GUIDELINES…………….……………..
INSTALLATION………………………………..….
General………………………………………..…
Included
Accessories…………………..…
Optional
items…………………………..…..
Warning
for
Installations………..….....
High
‐
altitude
region
support
functions…
T
‐
H2
‐
OS
Installation…………………….…
T
‐
H2
‐
DV
Installation………..…………..…
Venting
Instructions……………………....
Gas
Supply
/
Gas
Pipe
Sizing………...…
Water
Connections……………..……….…
Pressure
Relief
Valve………………………
Condensate
drain…………………………..
Electrical
Connections…………….........
Remote
Controller
Connection…….…
Pump
Control
Connection………..…….
Pump
Control
Mode…………………….…
Easy
‐
Link
System…………………………....
APPLICATIONS...…………………………………
Space
Heating……….………….……………
INITIAL
OPERATION..…………………….……
OPERATING
SAFETY……………………………
NORMAL
OPERATION…………………………
General………..……….………….……………
Temperature
settings.…….…..…………
Flow……………………………………………….
Freeze
Protection
System…….…………
Maintenance
and
Service………………
Unit
Draining
and
Filter
Cleaning……
TROUBLESHOOTING……..……………………
General………..……….………….……………
Error
codes.…………………….…..…………
COMPONENTS
DIAGRAM………………..…
PARTS
LIST………………….………………………
OUTPUT
TEMPERATURE
CHART……...…
WARRANTY………………….…………………….
2
3
4
5
6
6
7
8
9
9
10
10
17
19
20
20
23
24
25
26
28
32
32
34
35
37
37
37
39
39
40
40
41
41
43
45
48
50
51
Takagi reserves
the
right
to
discontinue,
or
change
at
any
time,
specifications
or
designs
without
notice
and
without
incurring
obligations
.
*40
psi
or
above
is
recommended
for
maximum
flow
NOTE
*Check
the
rating
plate
to
ensure
this
product
matches
your
specifications.
*In
accordance
with
ANZI
Z21.10.3
and
SCAQMD
Rule
1146.2,
CO
emission
does
not
exceed
400
PPM
for
normal
input
Installation
Manual
Owner’s