Installation
22
│
Page
•
The
condensate
drain
is
at
atmospheric
pressure
(non
‐
pressurized)
and
therefore
must
be
allowed
to
drain
freely
with
gravity
only.
Please
ensure
that
there
are
no
blockages
along
the
condensate
drain
tube.
All
portions
of
the
condensate
drain
(neutralizer
and
drain
tube)
must
be
at
a
lower
elevation
than
the
T
‐
H2
‐
DV/T
‐
H2
‐
OS
to
prevent
condensate
water
from
building
up
inside
the
heat
exchanger.
•
Condensate
cannot
be
effectively
neutralized
if
the
neutralizer
elements
inside
the
TH
‐
NT01
have
been
completely
consumed.
Condensate
will
remain
acidic
and
can
possibly
cause
damage
to
items
such
as
pipes,
concrete,
etc.,
if
drained
improperly.
•
The
TH
‐
NT01
Neutralizer
cartridge
is
designed
to
last
for
3
years
before
replacement.
However,
the
actual
life
of
the
neutralizer
may
vary,
depending
on
the
application
and
usage.
Please
ensure
that
the
cartridge
is
properly
replaced
before
the
neutralizer
elements
have
been
completely
consumed.
•
All
preventative
measures
and
safety
practices
must
be
adhered
to
when
draining
condensate.
TAKAGI
will
not
be
responsible
for
any
damage
caused
by
condensate.
•
A
drain
pan,
or
other
means
of
protection
against
water
damage,
is
required
to
be
installed
under
the
water
heater
in
case
of
leaks.
WARNING