Normal
Operation
37
│
Page
•
The
T
‐
H2
‐
DV/T
‐
H2
‐
OS
will
display
the
set
temperature
on
the
3
‐
digit
7
‐
Seg.
LED
on
the
computer
board.
This
LED
is
visible
through
a
small
window
on
the
unit’s
front
cover.
•
If
the
TM
‐
RE30
is
installed,
refer
to
the
TM
‐
RE30
Installation
Manual
included
with
the
remote
for
setting
temperature.
T
‐
H2
‐
DV/T
‐
H2
‐
OS
•
Flow
rate
to
activate
the
T
‐
H2
‐
DV/T
‐
H2
‐
OS
:
0.5
gallon
per
minute
•
Flow
rate
to
keep
the
T
‐
H2
‐
DV/T
‐
H2
‐
OS
running
:
0.4
gallon
per
minute
H
ot
Water
temperatures
over
125
°
F
can
cause
severe
burns
instantly
or
death
from
scalding.
•
The
outlet
hot
water
temperature
of
the
T
‐
H2
‐
DV/T
‐
H2
‐
OS
water
heater
is
factory
set
at
120
°
F.
•
Feel
the
water
temperature
before
bathing
or
showering.
NORMAL
OPERATION
GENERAL
1.
Open
a
hot
water
tap.
2.
Mix
cold
water
with
the
hot
to
get
the
correct
temperature
water.
3.
Close
the
hot
water
tap.
WARNING
TEMPERATURE
SETTINGS
‐
ON
THE
T
‐
H2
‐
DV/T
‐
H2
‐
OS
‐
On
T
‐
H2
‐
DV/T
‐
H2
‐
OS,
changing
the
temperature
setting
can
be
done
simply
by
using
the
3
‐
digit
7
‐
seg.
LED,
and
the
“Increase”
&
“Decrease”
buttons
on
the
computer
board
(TM
‐
RE30
remote
controller
is
not
required)
WARNING