Troubleshooting
44
│
Page
‐
FAULT
ANALYSIS
OF
ERROR
CODES
‐
If
there
is
a
problem
with
the
installation
or
the
T
‐
H2
‐
DV/T
‐
H2
‐
OS,
it
will
display
a
numerical
error
code
on
the
7
‐
seg
LED
of
the
computer
board
or
the
TM
‐
RE30
(if
installed)
to
communicate
the
source
of
the
problem.
Error
Code
Malfunction
description
Diagnosis
031
Incorrect
dipswitch
settings
Check
the
dipswitch
settings
on
PCB
101
Warning
for
the
“991”
error
code
Call
TAKAGI
Technical
Dept.
at
1
‐
888
‐
882
‐
5244
111
Ignition
failure
Check
gas
supply
121
Loss
of
flame
311
Output
thermistor
failure
Call
TAKAGI
Technical
Dept.
at
1
‐
888
‐
882
‐
5244
321
Inlet
thermistor
failure
331
Mixing
thermistor
failure
341
Exhaust
thermistor
failure
(Only
T
‐
H2
‐
DV)
391
Air
‐
fuel
Ratio
Rod
Failure
441
Flow
Sensor
Failure
(Only
Easy
‐
Link
system)
510
Abnormal
Main
Gas
Valve
551
Abnormal
Gas
Solenoid
Valve
611
Fan
Motor
Fault
621
Exhaust
fan
motor
Fault
(Only
T
‐
H2
‐
DV)
631
Abnormal
External
Pump
651
Water
Control
Valve
Fault
(Flow
Adjustment
function)
(Only
Easy
‐
Link
system)
661
Water
Control
Valve
Fault
(Bypass
valve
function)
701
Computer
board
Fault
711
Gas
Solenoid
Valve
drive
circuit
failure
721
False
Flame
Detection
741
Miscommunication
between
T
‐
H2
‐
DV/T
‐
H2
‐
OS
and
TM
‐
RE30
761
Miscommunication
in
Easy
‐
Link
941
Abnormal
exhaust
temperature (Only
T
‐
H2
‐
DV)
991
Imperfect
combustion