9
Page
Installation
Installation Manual
INCLUDED ACCESSORIES
Check that these items below are included with the water heater
Installation Manual
and Owner’s Guide
Temperature Remote Controller kit*
Outdoor model only
Bird Screen
Indoor model only
Qty: 1
Qty: 2
Qty: 1
*For more information on optional items, please refer to p32 to 33
CLEARANCES
Maintain all clearances around
the water heater
Model
Top
Bottom
Front
Back
Sides
140 Indoor
(T-H3M-DV)
12 in
(305 mm)
12 in
(305 mm)
4 in*
(102 mm)
1 in
(25 mm)
3 in
(76 mm)
140 Outdoor
(T-H3M-OS)
36 in
(914 mm)
12 in
(305 mm)
24 in
(610 mm)
1 in
(25 mm)
3 in
(76 mm)
*24 inches recommended for maintenance
Top
Back
Side
Side
Front
Bottom
Do not install this water heater under an
overhang less than 3 ft (914 mm) from its top,
top of exhaust part, or eaves The area under
an overhang must be open to three sides
(Outdoor models only)
Do not install the water heater exhaust port
within 1 ft (305 mm), in the USA, of any air
intake or building opening, and within 3 ft (914
mm), in Canada, of any air intake or building
opening (Outdoor models only) (Refer to p17)
3 ft
(914 mm)
exhaust port
A
A: 1 ft (305 mm) USA/3 ft (914 mm) Canada
A
A