- 7 -
WARNING FOR INSTALLATION LOCATIONS
Do not install the heater where water, debris
or flammable vapors may get into the flue
terminal. This may cause damage to the
heater and void the warranty.
Do not have the vent terminal pointing toward
any opening into a building. Do not locate
your heater in a pit or location where gas and
water can accumulate.
Do not install this water heater under an
overhang less than 3 feet from its top or
eaves. The area under an overhang must be
open to three sides.
Do not install the water heater vent terminator
within 1 ft. in the USA of any air intake or
building opening, and with in 3 ft. in Canada
of any air intake or building opening. (Refer to
p.14)
Do not install next to a dryer or any source of
airborne debris that can be trapped inside the
combustion chamber, unless the system is
direct vented.
Prohibited
Prohibited
3 Ft.