- 8 -
The dark square is the direction
the dipswitch should be set to.
Keep the clearances.
OUTDOOR INSTALLATION
1.
Follow all local codes, or in the absence of local codes, follow the most recent edition of
the National Fuel Gas Code: ANSI Z223.1/NFPA 54 in the USA or CAN/CSA B149.1
Natural Gas, Propane Installation Code in Canada.
2. Install outdoors only in areas with mild, temperate climates.
3.
Ensure that the unit is set for outdoor installation. Locate the bank of dipswitches
to the
right
of the 7-Seg. LED on the computer board. The ‘OUT’ dipswitch on the computer
board should be switched to its ‘ON’ (up) position (Do not adjust the bank of dipswitches
above the LED’s).
4.
The outdoor vent cap must be used when unit is installed outdoor. Takagi requires the
use of its part No. TK-TV04.
5.
When installed outdoors, the T-K3/T-K3-Pro water heater shall be wall-mounted or
mounted on a stand. Locate the water heater in an open, unroofed area and maintain
the following minimum clearances:
ING
Make sure power to the unit is
turned OFF before changing
the dipswitch settings.
There is a 2” clearance from the left
and right sides of the unit to
combustible and non-combustible
surfaces. However, if any portion or
area of the surface is exposed to the
exhaust fumes (i.e. directly to the sides
of the vent cap), that surface must be
at least 24” away.
*
Side 24”
*
Side 24”
Right Bank of Dipswitches
7-Seg LED
Right bank of
dipswitches
Left bank of
dipswitches
Top 36”
Back 1”
Front 24”
Bottom 12”
Side 2”
Side 2”