1 . Temperature remote controller: TK-RE02 Please refer to the remote controller manual supplied with the remote .
The temperature remote controller has two functions . It allows the output
temperature from the water heater to be adjusted within the range of 37 .5
°C to 75 °C (99 °F to 167 °F)*, and it also works as a diagnostic tool that will
give a concise error code whenever there is a problem with the unit . The
temperature options are 37 .5 °C (99 °F), 38 °C (100 °F), 39 °C (102 °F), 40 °C
(104 °F), 41 °C (106 °F), 42 °C (108 °F), 43 °C (110 °F), 44 °C (111 °F), 45 °C
(113 °F), 46 °C (115 °F), 47 °C (117 °F), 50 °C (122 °F), 55 °C (131 °F), 60 °C
(140 °F), 70 °C (158 °F), and 75 °C (167 °F) . See the troubleshooting section
for information on possible error codes .
*The remote only provides the temperature display in Fahrenheit .
2 . Temperature remote controller: TM-RE30 Please refer to the remote controller manual supplied with the remote .
The temperature remote controller has two functions . It allows the output
temperature from the water heater to be adjusted within the range of 37 °C
to 85 °C (100 °F to 185 °F), and it also works as a diagnostic tool that will
give a concise error code whenever there is a problem with the unit . The
temperature options are 37 °C (100 °F), 38 °C (100 °F), 39 °C (102 °F), 40 °C
(104 °F), 41 °C (106 °F), 42 °C (108 °F), 43 °C (110 °F), 44 °C (111 °F), 45 °C
(113 °F), 46 °C (115 °F), 47 °C (117 °F), 50 °C (122 °F), 55 °C (131 °F), 60 °C
(140 °F), 65 °C (149 °F), 70 °C (158 °F), 75 °C (167 °F), 80 °C (176 °F) . See
the troubleshooting section for information on possible error codes .
3 . 4 inches universal appliance adapter with back flow preventer and condensation drain: 9008146005 / 2SVBFDPA04
There are three functions available for this adaptor, which can be connected
with the water heater and Flex master venting line and prevents the backflow
of air through the exhaust vent . This helps prevent harmful exhaust gases
from entering the home, as well as helping to prevent the unit from freezing
in areas where cold air can be blown or drawn into the exhaust system .
Furthermore condensation drain from the combustion is discharged . Install
this adaptor in accordance with the installation instructions that are packaged
with the adaptor and any applicable codes .
4 . Direct-vent conversion kit: TK-TV10
This kit can be used to convert the water heater from a standard vent system
to a direct-vent (or sealed combustion) system . Install this conversion kit in
accordance with the installation instructions and any applicable codes .
5 . Pipe Covers: TK-PC01 and TK-PCJr2
The pipe cover protects the plumbing pipes to the water heater from
unexpected adjustments . This pipe cover is fixed to the bottom of the water
heater, which hides the plumbing and improves the visual aspects of the whole
installation for the water heater .