- 2 -
CONTENTS
*40 psi or above is recommended for maximum flow
NOTE
*All references to the T-M50 also refer to the
T-M50 ASME model
*Check the rating plate to ensure this product
matches your specifications.
*In accordance with ANSI Z21.10.3 and
SCAQMD Rule 1146.2, CO emission does not
exceed 400 PPM for normal input
SPECIFICATIONS
Natural Gas Input
(Operating Range)
Min: 15,000 Btu/h
Max: 380,000 Btu/h
LPG Input
(Operating Range)
Min: 15,000 Btu/h
Max: 380,000 Btu/h
Gas Connection
1” NPT
Water Connections
1” NPT
Water Pressure
15 - 150 psi *
Natural Gas Pressure
Inlet
Min. 5” WC
Max. 10.5” WC
LP Gas
Pressure Inlet
Min. 8” WC
Max. 14” WC
Manifold Pressure
Natural: 2.8” WC
Propane: 3.8” WC
Weight
112lbs.
Dimensions
H25.3”
×
W24.8”
×
D11.8”
Ignition
Electric Ignition
Supply
120VAC (60Hz)
Operation
178 W
(1.48A)
Standby
16 W
(0.13A)
Electric
Consumption
Freeze-
Protection
271 W
(2.26A)
SPECIFICATIONS……………………….
INTRODUCTION…………………………
SAFETY GUIDELINES………………....
INSTALLATION…………………………..
General…………………………………
Included Accessories…….……………
Outdoor Installation……………………
Indoor Installation…………………......
Direct Intake Vent System…………….
Venting Instructions………………......
Gas Supply / Gas Pipe Sizing………..
Water Connections……………………
Pressure Relief Valve…………………
Electrical Connections……………......
Remote Controller Connection………
Pump Connection… … … … … … …
Easy Link System … … … … … … …
Multi-Unit System………………………
Initial Operation………………………..
NORMAL OPERATION………………….
Normal Operation…………………......
Flow……………………………………..
Freeze Protection System…………...
Temperature Settings………………….
Maintenance and Service…………….
GENERAL TROUBLESHOOTING… … .
WIRING DIAGRAM …………………… ..
OPERATING SAFETY…………………..
APPLICATIONS………………………......
Re-Circulation……………...................
Dual-Purpose Heating………………...
ADDITIONAL CLEARNCES……………..
OPTIONAL ITEMS………...……………..
COMPONENTS DIAGRAM…………….
PARTS LIST………………………………
OUTPUT TEMPERATURE CHART……
PRODUCT REGISTRATION AND
LIMITED WARRANTY……………….......
2
3
5
6
7
7
8
10
11
12
16
18
19
20
21
22
24
27
29
30
30
32
32
33
34
35
38
39
41
41
42
43
44
45
49
51
51
Takagi reserves the right to discontinue, or change at any time, specifications