If the TM-RE30 remote controller (optional) is used, it has to be connected to the “
MASTER
”
unit. If the TM-RE30 is connected to a “
SLAVE
” unit,
it will only control that particular
individual “
SLAVE
” unit and will not control the Easy Link system as a whole.
MULTI-UNIT SYSTEM FOR LARGE VOLUMES
Multiple T-M50’s can be combined for a Multi-Unit system, along with the Multiple Unit
Controller and Remote Controller (Parts TM-MC01 and TM-RE30). Each set of controllers (one
TM-MC01 and one TM-RE30) can control from 2 units to 10 units for commercial or residential
applications. For a 10-unit system, the computer can modulate between the usage of 15,000
BTU/h to 3.8 Million BTU/h.
•
The TM-RE30 (optional remote controller) is not required for the Easy Link
system.
•
If running the Easy Link system without the TM-RE30, please make sure the
dipswitch settings for the temperature, outdoor, and direct vent settings on
ALL the units are set to the same settings. Otherwise, the units may not
operate properly.
•
If the TM-RE30 is used, the temperature on all the units in the system will
automatically be set to the same temperature that is set on the remote.
However, even with the remote, the outdoor and direct vent dipswitch
settings still need to be set to the same settings on all the units.
MASTER unit
SLAVE unit
Wrong connection
between the “
SLAVE
”
unit and the TM-RE30
MOBIUS Water
Heater Model
T-M50
Cold IN
Hot Out
TM-MC01