background image

Installation of Basin Unit

1

(1) Set the dedicated paper template on the floor, and align it with the 

         water, hot water, and drainage pipe risers.

(2) Mark the bolt anchor position of the basin unit.

(3) Drill holes at the bolt anchor position of the basin unit.

(4) Remove the paper template.

Align the basin unit with the marked positions on the floor and anchor the unit with the bolts (6 locations).

3

Fixing the Basin Unit on the Floor

1

Marking the bolt anchor points

(1) Drill open a hole of the 

specified diameter and 

depth.

(2) Remove the dust from each 

anchor hole by cleaning 

with a vacuum cleane r.

(3) Insert the anchor bolt and 

tap it with a hammer until 

the center pin makes 

contact with the bolt head.

(4)Adjust the fastening 

strength of the nut 

using a wrench.

Floor

Supplied 

template

8.5 mm

Hole depth 

2.0

 or

 more

Nut

Flat washer

Center pin

0.1
0.2

~

Bolts to be used (supplied with the shampoo unit):

 Plywood Floor

     Hexagonal head tapping bolt + flat washer 

     (8 mm x 65)

 Concrete Floor

     Anchor bolt + plain washer

     (M8 x 70, Pilot drill hole 8.5 mm

(

0.33

)

     (Use the wrench with the opposite side distance of 1/2

.)

Be sure to use a plain washer when securing the bolt.

Request measures to prevent water leakage under the floor and downstairs

Be sure to take the necessary precautions to prepare for and prevent 

possible water leaks.

•  Use waterproof flooring materials.

•  If the floor has an opening, cover the opening when completing 

     the interior finishing (waterproofing).

•  Install all pipe packings.

2  Attach pipe packing

(1) Cut a slit in the pipe packing to suit the position of the pipes to be installed.

(2) Peel away the sheet from the adhesive surface of the pipe 

packing and stick to the floor surface.

(3) Cut out a circle around the slit cut in the pipe packing to suit the 

pipe surface, and fill in any gaps with caulking materials.

Caution

• Always attach pipe packing and apply caulking materials to the areas around

   the pipes so that there are no gaps, in order to prevent condensation within

   YUME-iXi or water seeping on the floor in the event of water leaks.

• If pipe packing is not used, condensation may cause water to pool on the

   floor, structural parts may start degrading and malfunctions may occur.

Installation process for anchor bolts

Caution

Caution

The strength of the anchor bolts will be reduced

 if they are hammered into the hole while touching

 the bottom. Open up a gap.

7

Pipe packing

(sponge)

Cut a slit

Attach pipe 

   packing

Apply caulking materials

    to any gaps

Water Supply Pipe

 

Hot Water 

Supply Pipe

Drain Pipe

 

YUME

-iXi

 

Paper T

em

pla

te

Paper Template

Summary of Contents for YUME-iXi

Page 1: ...Xi can be installed safely and to prevent any danger or risk to the person installing YUME iXi or those around them All of these precautions are important for safety Takara Belmont is not responsible...

Page 2: ...eburr the ends of cut pipes Avoid using inverted U shaped pipes siphon as these can cause air to become trapped Always connect hot water pipes and water supply pipes after removing all contaminants su...

Page 3: ...r softener to prevent the buildup of scale within the basin body Aeration may be minimal when using shampoo even if drinkable well water is used so a water softener should be installed Use a pressure...

Page 4: ...crew Set for Cover Step Step low type type Maintenance Cover small Base cover Trap cover Head pillow 2 Mohair tape Maintenance Cover Installation instructions 1 Operating Manual 1 Paper template 1 YUM...

Page 5: ...onal head bolts phillips head M8 x 50mm from the unit base four locations Detach the basin unit from the skid Carrying the Basin Unit 1 Carrying the main body Attach the carriage jig to the seat frame...

Page 6: ...basin Do not hold the main body cover Doing so may cause damage to the main body cover Take care when handling the basin as it is heavy and fragile Do not drag the unit The foot part of the basin is...

Page 7: ...event water leakage under the floor and downstairs Be sure to take the necessary precautions to prepare for and prevent possible water leaks Use waterproof flooring materials If the floor has an openi...

Page 8: ...e 1 2 female screw Turn valve Not included Flexible pipe Not included Caution Before piping installation Hair trap Drain hose Turn valve and Flexible pipe is not included Prepare those parts that suit...

Page 9: ...test the water flow to prevent accidents during use Test the water flow and inspect the following items The hot water may be slightly tainted at the start of the water flow test however this does not...

Page 10: ...Caution Attach the two locations on the top of the step slide rail to the basin unit using truss head screws M6 x 15 2 screws Assemble while the step is retracted packing state Tighten the screws whi...

Page 11: ...he step is installed while it is slided out this could lead to the step rattling poor sliding operation and noise Ensure the step is installed while fully retracted Fully tighten the truss head screws...

Page 12: ...the leg rest using hexagonal head bolts M6 x 15mm 2 bolts Velcro Back support cusion Velcro Screen sheet 3 Attaching the Seat Part Attach the legrest Attach the edge of seat to the legrest by velcro...

Page 13: ...0mm Black 6screws Remove the maintenance cover and the base cover Maintenance cover Base cover Check that pressing the reclining pedal with your foot reclines the backrest and lifting your foot off th...

Page 14: ...s in as a fulcrum while pushing both edges inwards Position the screw sections so they pass through the trap cover attachment holes and when the screws emerge from below fix with urea cosmetic nuts Pu...

Page 15: ...ter leaks on the floor 1 Set the neck cushion to the metal fittings in the direction as shown in the image 3 Adjust the shape of the neck cushion to suit the metal fittings and attach the basin side s...

Page 16: ...water supply position Water supply position Drain position Wall surface or furniture Wall surface or furniture Step front back slide Figures shown above are for seating a customer about 170cm in heig...

Page 17: ...e peeled off area The panel surface should be higher than the surrounding tile or glass surface within 1 16 or 1 8 Show the floor installation surface Caution for Anchor Bolt Installation Anchor bolts...

Page 18: ...18...

Page 19: ...19...

Page 20: ...20 NOTE 1E043YA0 1 1 2 Chome Higashi shinsaibashi Chuo ku Osaka Japan 101 Belmont Drive Somerset NJ 08873 800 526 3847 TAKARA BELMONT CORPORATION Book Number U S A JAPAN...