Adjusting the water temperature

*For safety reasons, this product is designed so that hot water of approximately 53°C or higher is not output.

(Conditions: In the case that the supply pressure of water and hot water are the same, normal water temperature is 20°C 
and hot water temperature is 60°C.)

1

  

Turn the thermostatic control knob in the H or C direction to set the 

temperature to an appropriate level.

When turning to the H direction, water becomes warm, and when 

turning to the C direction, water becomes cold.

2

  

To use hot water at high temperature (40°C and higher), turn the 

thermostatic control knob in the H direction while holding down the 

stop button.

When adjusting the water temperature, reduce the volume of water,

point the shower head away from the client and check the

temperature by hand. Take care when doing so, as hot water may

come out of the shower head.

Return the thermostatic control knob to an appropriate position after use. Continuing to use the hot water with the 

knob in the hot temperature position may cause burns.

Using other equipment that shares the same water/hot water supply source at the same time may cause unstable 

water temperature. Do not execute any quick operation while adjusting the temperature.

Operate the thermostatic control knob only after removing metallic objects such as rings and wrist watches, etc. 

Failure to follow this instruction may result in contact between the metal and cap of thermostatic control knob resulting 

in scratches or cracks on the plated surface and thereby causing peeling of the plating.

Before using the product, check that there are no scratches, cracks, or peeling of the plated surface of the thermostatic 

control knob. If the plating is peeled off, immediately stop using the product and contact the nearest dealer or Takara 

Belmont directly as it may result in personal injury. Continued operation may result in personal injury.

Caution

Caution

Depends on the operating environment or conditions, the water discharge amount may change significantly when 

controlling the hot water temperature. This phenomena occurs when the hot water temperature exceeds the 

recommended values (60°C to 80°C), there is significant difference in the water supply or hot-water supply 

pressure, or multiple devices are used at the same time – it is not a product failure.

The temperature of discharged water and the preset temperature may differ depending on the operating 

environment or conditions.

(The product is designed so that the temperature of the discharged water will be about 40°C when the thermostatic 

control knob is turned toward the H position and locked in that position.)

This phenomena occurs when the hot water temperature exceeds the recommended values (60°C to 80°C), there is 

significant difference in the water supply or hot-water supply pressure, or multiple devices are used at the same 

time - it is not product failure. The temperature of discharged water may be set at approximately 40°C when the 

temperature of hot water or the pressure of the water/hot water supply is adjusted and the locking position of the 

thermostatic control knob is adjusted.

Note

Note

Depends on the environment or condition that it is used in, the product may have the following conditions. If adjust-

ment or replacement is required, contact the nearest dealer or Takara Belmont directly.

A gushing sound may be emitted from the basin unit. (Adjustment is required.) This sound is due to water flowing 

fast through pipes as a result of high water pressure or water volume control, and is not indicative of a defective 

product. This gushing sound may be reduced by adjusting the water pressure.

The tap may become stiffer. (Replacement is required.)

This is due to deterioration of gasket of movable parts or a lack of grease as a result of aging. Replacement of the 

gasket or other parts, or a recoating of grease is required. (available at additional cost)

Stop Button

Hot 

Thermostatic 

Control Knob

Cold

Thermostatic

Control Knob

    (H) Hot

   (C) Cold

Summary of Contents for YUME SWING

Page 1: ...esin Plated Parts Types of Layout and Standard Positions Preparation How to Use Guiding Clients Care and Maintenance Daily Inspections Before Requesting Repairs Parts Replaced on a Regular Basis Stand...

Page 2: ...not be conducted by people other than qualified repair technicians Failure to follow this instruction may cause water leakage or abnormal operation leading to injury Safety Precautions Adhere to these...

Page 3: ...o injury Also coloring dyes on the neck cushion or basin may stain the user s clothes Do not use hot water boiling water of 60 C or higher Using hot water of 60 C or higher may deform or damage the ba...

Page 4: ...sure to only use this product inside a hairdressing salon Failure to follow this instruction may cause malfunction or damage to the main unit Take care when handling the shower hose When using the bas...

Page 5: ...gienic conditions Try to clean the hair catcher after each shampoo Do not cover the drain outlet when this product is not going to be used Do not cover the drain outlet with the drain cap towel or sha...

Page 6: ...brasive compound Do not use an abrasive compound to clean the dual function shower head shower head holder cover etc Use of an abrasive compound sponge with abrasive compound or hard cleaning tools su...

Page 7: ...product Check the position of the basin and SWING arm before rotating the chair Depends on the fixed position of the chair foot footrest will hit the basin unit resulting in breakage of the chair or...

Page 8: ...when manufacturing the part and these are not a product failure Position of Warning Labels 8 Caster Cover Dual function shower head Shower Hose Rotation Arm Cover Maintenance Cover Caster Rail Neck Cu...

Page 9: ...ccessories have been attached properly Caster rail is to prevent floor from getting scratched while the caster of basin unit slides Please note in advance that surface of caster rail may degrade due t...

Page 10: ...ce when a hard object hits the surface Peeling of the plating may occur from scratches or cracks on the plated surface Check to ensure that there are no scratches cracks or peeling of the plated surfa...

Page 11: ...eck the Initial Position and Shampooing Position from the illustrations shown below Initial Position Shampooing Position Initial Position Shampooing Position Front Layout Rear Layout Wall Wall Wall Wa...

Page 12: ...the proper direction 2 Secure the snap buttons of neck cushion on the chair side to the fixing pins of metal fittings 3 While shaping the neck cushion along the metal fittings secure the snap buttons...

Page 13: ...il they snap into place Attach the sponge to the shower hose Attach the sponge and sponge holder to the shower hose between the shower head holder and the cover Do not remove the cover of holder forci...

Page 14: ...l stop the water When the basin is not being used turn the tap firmly full right clockwise to turn the water off properly Failure to do this may cause water leakage After shampooing do not cover the d...

Page 15: ...rsonal injury Caution Caution Depends on the operating environment or conditions the water discharge amount may change significantly when controlling the hot water temperature This phenomena occurs wh...

Page 16: ...not affect use A small amount of water may flow out but does not affect its convenient use If the decreasing level is significant the gasket of the drain cap may have deteriorated or become worn so r...

Page 17: ...and chair backrest When sliding the basin unit hold the edge of the basin and slide it Basin unit is locked at initial position and at shampooing position Slight click is felt when the basin is locke...

Page 18: ...seals attached to the chair base and lower cover 3 Unlock the chair rotation after the client seats on the chair and rotate it to the shampooing position 4 Slide the basin unit to shampooing position...

Page 19: ...with the basin When reclining the backrest hold the client s head by your hand to avoid client s head to hit the basin When unlocking the chair rotation while the client is laying on the chair to do...

Page 20: ...separately Product code ES ESST Adjusting the height of ESPOIR Stool 1 While seating on the stool raise the handle and release the lock 2 Adjust it to the desired height 3 Return the handle and lock...

Page 21: ...of product or personal injury When returning the basin unit return it to the initial position completely Failure to follow this instruction may allow the basin unit to contact to chair etc resulting...

Page 22: ...e to wipe off any moisture from all parts other than the basin Leaving the product with water drops may result in failure of the product or any contamination will not be removed Caution The drain cap...

Page 23: ...it is extremely dirty or the surface has deteriorated available at additional cost At the end of work each day wash the neck cushion and head pillows with water wipe them dry with a towel and allow t...

Page 24: ...water Clean it once a month measure Using a nylon or similar brush remove the dirt such as water stain from the foaming water outlet 4 Re assemble the shower head 1 Insert the foaming water outlet an...

Page 25: ...with both hands Clean the sponge every day After cleaning the sponge put it in the hose and put it back on the cover Sponge is consumable supply Replace the sponge if degradation causes rubbing sound...

Page 26: ...hen the basin is filled with water available at an additional cost Basin body Drain cap Gasket Drain cap Drain cap Removing water from filter and cleaning the filter When removing maintenance cover an...

Page 27: ...filters 4 With cloth cover the floor around the water and hot water supply pipes 5 Close stop valves of the hot water and water supply pipes If there are electrical components such as wires nearby ens...

Page 28: ...ter leakage 11 Return the maintenance cover to its original position using the Urea screw 1 pce removed at the process 1 10 Return the plumbing cover to its original position using the Urea screw remo...

Page 29: ...oca tions in total and detach the caster covers When the hair or dirt tangled with caster and it does not move smoothly clean the caster 2 Remove hair and dirt tangled with caster and clean it 3 Retur...

Page 30: ...temperature setup of the thermostatic control knob proper Is hair clogging the hair catcher Adjust the volume of the water Refer to pages 14 to 15 Adjust the temperature setup of the boiler to the pr...

Page 31: ...amage to the hose may result in water flooding on or beneath the floor Check valve Replace every three years When the check valve is used continuously for long periods of time there is a possibility t...

Page 32: ...pressure water pressure 0 1MPa respectively Dual function shower head Shower outlet 10 0L min Low splash foaming mode 6 5 L min Stop valve Single faucet rotary type Operating environment Operating tem...

Page 33: ...floor plumbing Overview Diagram Basin EX YMSBXYM2 YUME Basin Reverse Slide Spec Arm EX YMSAF2 Front Layout Reverse Slide Spec Unit mm 233 850 50 210 569 1348 218 747 324 988 493 6 Shampooing position...

Page 34: ...er flows Refer to page 14 to 15 It may cause malfunction of the product or stain may become hard to remove Immediately wipe away the moisture adheres on the parts except inside of the basin There is a...

Page 35: ...nearest dealer or Takara Belmont directly If water is leaking from the drain hose the drain hose may be worn degraded or damaged Immediately stop using the product and contact the nearest dealer or Ta...

Page 36: ...1E04ZTB0 36 1 1 2 Chome Higashi shinsaibashi Chuo ku Osaka Japan TEL 81 6 6213 5945 FAX 81 6 6212 3680 TAKARA BELMONT CORPORATION Printed in Japan...