27
Maintenance Cover
Remove
Remove
Urea screw (with gasket)
2
Remove the Urea screw (1 pce. with gasket), and
detach the maintenance cover.
*Take care not to lose the Urea screw that has been
removed, since it will be attached again.
After removing the maintenance cover,
check that there is no water leakage inside of
the basin unit. If there is water leakage, the
pipes inside of the basin may be damaged.
Contact the nearest dealer or Takara
Belmont
1
Prepare cloth (two or more in A4 size) to soak up water.
Urea screws
Plumbing Cover
Close the
stop valves
Water
Supply Pipe
Hot Water
Supply Pipe
●
Valve is closed.
Drain Hose
To prevent water leakage, always check
that the stop valves are completely closed
before executing cleaning, or draining the
water from the filters.
4
With cloth, cover the floor around the water and hot
water supply pipes.
5
Close stop valves of the hot water and water supply
pipes.
・
If there are electrical components such as wires
nearby, ensure that water does not splash onto them.
Failure to follow this instruction may cause a ground
leakage fire.
・
The hot water supply pipe may become very hot.
Take care not to touch the pipe directly.
*Be careful of the rotation arm cover when doing this procedure.
After detaching the maintenance cover,
check that there is no water leakage inside
of the swing arm cover. If there is water
leakage, the pipes inside of
the swing arm cover may be damaged.
If this is the case, contact the nearest dealer
or Takara Belmont directly.
3
Detach the plumbing cover.
*Take care not to lose the Urea screws (4 pcs.) that have
been removed, since they will be attached again.
*In case that the mirror cabinet (sold separately) is also
installed, remove 2 pcs. of Urea screws.
Caution