Using via Digital Data Communication
101
STATus:MEASure:CONDition
: Retrieves Power Supply Status
Function:
Retrieves the status of the power supply
Format:
STATus:MEASure:CONDition?
Type:
QUERY command only
Response:
3 byte 16-base data
Power Supply Bit List
Bit
Status Name
Summary
1
0
23
P-ON(D)_STS
Internal power unit (D) P-ON
status
* 12 kW type only
Power unit power-on
Power unit power-off
22
P-ON(C)_STS
Internal power unit (D) P-ON
status
* 12 kW type only
Power unit power-on
Power unit power-off
21
P-ON(B)_STS
Internal power unit (B) P-ON status Power unit power-on
Power unit power-off
20
P-ON(A)_STS
Internal power unit (A) P-ON status Power unit power-on
Power unit power-off
19
ISO_OPTHION_MOUNT Isolated Option Mounting Status
Yes
None
18
Not Used
Always 0
-
-
17
EXT_TRIP_LT_STS
External TRIP Latch Status
TRIP ON
Normal
16
EXT_TRIP_STS
External TRIP Status
TRIP ON
Normal
15
OVP_STS
OVP Adjustment Status *1
Above OVP level
Below OVP level
14
OCP_STS
OCP Adjustment Status *1
Above OCP level
Below OCP level
13
Not Used
Always 0
-
-
12
EXT_ON
Toggling Output ON/OFF at
External Contacts
Input Status
ON
OFF
11
ALM_BUS_STS
(SYS_ALM)
System error
Error
Normal
10
DD_ON_BUS_STS
DC/DC Output Status
ON
OFF
9
MST/BST_STS
Master/Booster Status *2
Booster *2
Master
8
P-ON(B)_STS
P-ON(Booster) Status
Booster Main Power
Supply ON *2
Booster Main Power
Supply OFF *2
7
P-ON(M)_STS
P-ON(Master) Status
Main Power Supply ON
Main Power Supply OFF
6
Not Used
Always 0
-
-
5
OHP_ALM
OHP(Over Heating Protection)
Error
Error
Normal
4
OCP_ALM
OCP (Over Current Protection)
Alarm
Triggered
Not triggered
3
OVP_ALM
OVP (Over Voltage Protection)
Alarm
Triggered
Not triggered
2
Not Used
Always 0
-
-
1
CC_STS
CC Operation Status
CC operating
Not CC
0
CV_STS
CV Operation Status
CV operating
Not CV
*1 It is the status for factory adjustments of OVP and OCP. Practically, the status when OVP and OCP are running is
output to Bit4 OCP_ALM and Bit3 OVP_ALM
*2 Booster refers to the HX-S-G2 Series power supply that is running as a slave unit under parallel operation.
<Ex.>
STAT:MEAS:COND?
300180
(This shows the status where P-ON(B)_STS, P-ON(A)_STS, P-ON(B)_STS, and P-ON(M)_STS are 1.)
Summary of Contents for HX-S-G2 Series
Page 165: ...Special Loads 165 This page is blank...
Page 169: ...Maintenance 169 This page is blank...
Page 211: ...Specifications 211 External Diagrams 1 HX S 030 200G2 F I...
Page 212: ...Specifications 212 2 HX S 030 400G2 F I...
Page 213: ...Specifications 213 3 HX S 060 100G2 F I...
Page 214: ...Specifications 214 4 HX S 060 200G2 F I...
Page 215: ...Specifications 215 5 HX S 0120 50G2 F I...
Page 216: ...Specifications 216 6 HX S 0120 100G2 F I...
Page 217: ...Specifications 217 7 HX S 0400 15G2 F I...
Page 218: ...Specifications 218 8 HX S 0400 30G2 F I...
Page 219: ...Specifications 219 9 HX S 0500 12G2 F I...
Page 220: ...Specifications 220 10 HX S 0500 24G2 F I...
Page 221: ...Specifications 221 11 HX S 01000 6G2 F I...
Page 222: ...Specifications 222 12 HX S 01000 12G2 F I...
Page 223: ...Specifications 223...
Page 239: ......