Using via Digital Data Communication
86
MEASure:MVAV
:Sets Moving Average process for Measurement Values
Function:
Sets the Moving Average process for Measurement Values
Same as FUNCTION Settings Item 11
Format:
MEASure:MVAV <NRf>
Type:
SET command, QUERY command
Parameters:
0: Moving Average for measured value is not processed
1: Moving Average for measured value is processed
Response:
Same as parameters
Restrictions:
Alarm response is returned for normal SET commands in the following conditions
·
While operating as a series operation slave unit
·
While operating as a parallel operation slave unit
<Ex.>
MEAS:MVAV 0
MEAS:MVAV?
0
MEASure[:SCALar]:CURRent[:DC]
:Retrieves Current Measurement Values
Function:
Retrieves current measurement values.
Format:
MEASure[:SCALar]:CURRent[:DC]?
Type:
QUERY command only
Response:
Returns same resolution data as the Ammeter
Restrictions:
Alarm response is returned for normal SET commands in the following conditions
·
While operating as a parallel operation slave unit
<Ex.>
MEAS:CURR?
100.0
MEASure[:SCALar]:VOLTage[:DC]
:Retrieves Voltage Measurement Values
Function:
Retrieves voltage measurement values
Format:
MEASure[:SCALar]:VOLTage[:DC]?
Type:
QUERY command only
Response:
Returns same resolution data as the Voltmeter
Restrictions:
Alarm response is returned for normal SET commands in the following conditions
·
While operating as a parallel operation slave unit
<Ex.>
MEAS:VOLT?
60.00
Summary of Contents for HX-S-G2 Series
Page 165: ...Special Loads 165 This page is blank...
Page 169: ...Maintenance 169 This page is blank...
Page 211: ...Specifications 211 External Diagrams 1 HX S 030 200G2 F I...
Page 212: ...Specifications 212 2 HX S 030 400G2 F I...
Page 213: ...Specifications 213 3 HX S 060 100G2 F I...
Page 214: ...Specifications 214 4 HX S 060 200G2 F I...
Page 215: ...Specifications 215 5 HX S 0120 50G2 F I...
Page 216: ...Specifications 216 6 HX S 0120 100G2 F I...
Page 217: ...Specifications 217 7 HX S 0400 15G2 F I...
Page 218: ...Specifications 218 8 HX S 0400 30G2 F I...
Page 219: ...Specifications 219 9 HX S 0500 12G2 F I...
Page 220: ...Specifications 220 10 HX S 0500 24G2 F I...
Page 221: ...Specifications 221 11 HX S 01000 6G2 F I...
Page 222: ...Specifications 222 12 HX S 01000 12G2 F I...
Page 223: ...Specifications 223...
Page 239: ......