Controlling with External Analog & Contact Signals
134
Setting Procedures
Press the Function "FUNC." key.
The FUNC. lamp will light.
The Setting Item Number will be displayed in the Number Display
(voltage) and the parameter will be displayed in the Number
Display (current).
Select Item number 10 with the VOLTAGE dial.
Select 0 to 2 with the CURRENT dial.
Set value 0: Turns off ON/OFF Toggle by external contact
(invalid).
Set this if controlled by the front panel’s ON/OFF
key or by remote control (command).
Set value 1: Sets Output ON if the external contact is closed
and OFF if the external contact is opened.
Set this if output is controlled by external contact.
Output control by the front panel’s ON/OFF key or
remote control (commands) is invalid.
Set value 2: If the external contact is closed, power control by
the front panel’s ON/OFF key or remote control
(commands) is enabled. If it is open, the output is
set to OFF.
Press the FUNC. key again to finish.
Confirms settings and returns the Number Display to
measurement display mode.