Controlling with External Analog & Contact Signals
147
Output Current Control with External Voltage
*This function can not use 1000V type.
Outputs current, which is proportionate to the direct current voltage
added from external voltage.
Outputs from 0 to the maximum output current for external voltage of
0 to 10V.
The external voltage uses what can produce a 1mA current.
The output current is derived from the following formula.
Output Current [A]
=
10
]
[
Voltage
External
]
[
Current
Output
Maximum
V
A
The output accuracy for the external resistance is the set current ±
(0.5% of Rated Output Current).
Connecting
Connect the external voltage between No. 5 and 18 of the external control connector (accessory).
Setting Procedures
Set the parameter to 1 (External Voltage) according to the procedure on page
External Control Connector
5
Twisted-Pair Wire
18
Output Current Control via External Voltage
External Voltage
0~10V
The commons for analog signal (external control connector No. 18) is internally connected to the
minus side of the output terminal.
Isolation for the wire connecting to the external control should be more than the relative ground
voltage of this product.
Otherwise, the user may receive electric shock.
The External Resistance A, B, and C and the External Voltage cannot be used together to control
the output.
!
CAUTION
MAX
10V
0
External Voltage
O
u
tp
u
t C
u
rr
e
n
t
CC_EXT/V
Output Current Control with External Voltage
Summary of Contents for HX-S-G4 Series
Page 157: ...Special Loads 157 This page is blank...
Page 161: ...Maintenance 161 This page is blank...
Page 197: ...Specifications 197 External Diagrams 1 HX S 030 200G4 F I...
Page 198: ...Specifications 198 2 HX S 030 400G4 F I...
Page 199: ...Specifications 199 3 HX S 060 100G4 F I...
Page 200: ...Specifications 200 4 HX S 060 200G4 F I...
Page 201: ...Specifications 201 5 HX S 0500 12G4 F I...
Page 202: ...Specifications 202 6 HX S 0500 24G4 F I...
Page 203: ...Specifications 203 7 HX S 01000 6G4 F I...