Calibration
177
7. Set the constant voltage setting value to [ xV ] and
the external resistance to 0Ω and set the output to
ON.
30-200
30-400
60-100
60-200
[xV]
1.00V
1.00V
1.00V
1.00V
500-12
500-24
1000-6
1000-12
[xV]
1.0V
1.0V
1V
1V
On how to set, refer to Output Current Control with
External Resistance (A).(page143)
8. Press the FUNC. key.
9. Turn the VOLTAGE dial to display the setting item
number 31 in the Number Display (voltage).
* At that time, "C" or "F" is displayed in the Number
Display (current).
C: Coarse adjustment
F: Fine adjustment
10. Adjust so that the output current becomes [ yA ]
with the CURRENT dial.
30-200
30-400
60-100
60-200
[yA]
200.00A
400.00A
100.00A
200.00A
DMM display
value
50.00mV
40.00mV
25.00mV
50.00mV
500-12
500-24
1000-6
1000-12
[yA]
12.000A
24.000A
6.000A
12.000A
DMM display
value
40.00mV
40.00mV
30.00mV
40.00mV
※
*DMM display value is the specification of the shunt resistor
The value when had you use.
* Pressing the CURRENT dial switches the
adjustment between "C" (coarse adjustment) and
"F" (fine adjustment).
11. Press the FUNC. key to settle the full-scale
calibration value of output current control (A)
with external resistance.
12. This completes offset/full-scale calibration of
output current control with external resistance (A).
Set the constant voltage setting value and the
constant current setting value to the original ones
and start using.
Summary of Contents for HX-S-G4 Series
Page 157: ...Special Loads 157 This page is blank...
Page 161: ...Maintenance 161 This page is blank...
Page 197: ...Specifications 197 External Diagrams 1 HX S 030 200G4 F I...
Page 198: ...Specifications 198 2 HX S 030 400G4 F I...
Page 199: ...Specifications 199 3 HX S 060 100G4 F I...
Page 200: ...Specifications 200 4 HX S 060 200G4 F I...
Page 201: ...Specifications 201 5 HX S 0500 12G4 F I...
Page 202: ...Specifications 202 6 HX S 0500 24G4 F I...
Page 203: ...Specifications 203 7 HX S 01000 6G4 F I...