Specifications
191
Constant Voltage Characteristics
Specification/Models
30-200
30-400
60-100
60-200
500-12
500-24
1000-6
1000-12
Range
0.00V-31.50V
0.00V-63.00V
0.0V
-
525.0
0V-1050V
Accuracy *11
±
(
0.1%+5mV
)
of set
value
±
(
0.1%+10mV
)
of set
value
±
(
0.1%+0.1V
)
of set
value
±
(
0.1%+0.2V
)
of set
value
Resolution
10mV
0.1V
1V
Load Regulation *4
Below 0.01% + (0.005% of maximum output voltage)
Line Regulation *5
Below 0.01% + (0.005% of maximum output voltage)
Ripple (Effective Value)
*6
Below 10 mVrms
Below 50 mVrms
Below 100 mVrms
Noise(p-p value)(TYP)
*7
Below 100mVp-p
Below 300mVp-p
Below 300mVp-p
Temperature Coefficient
(Typical Value)
±100ppm/
℃
Recovery Time *8
1ms or less
2ms or less
Program
ming Time
*9
Rising
200ms±20%
(
full load
)
/200ms±20%
(
no load
)
200ms±20%
(
full load
)
/200ms±20%
(
no load
)
500ms±20%
(
full load
)
/500ms±20%
(
no load
)
500ms±20%
(
full load
)
/500ms±20%
(
no load
)
Falling
200ms±30%
(
full load
)
/Below /1200ms
(
no load
)
200ms±30%
(
full load
)
/Below 1200ms
(
no load
)
500ms±30%
(
full load
)
/Below 1200ms (no load
)
500ms±30%
(
full load
)
/Below 1200ms
(
no load
)
Maximum Sink Current
1A±20%
2A±20%
1A±20%
2A±20%
250mA±20%
500mA±20%
125mA±20%
250mA±20%
Residual Voltage when
OUTPUT is OFF (TYP)
± 10mV or less
± 25mV or less
± 50mV or less
Constant Current Characteristics
Specification/Models
30-200
30-400
60-100
60-200
500-12
500-24
1000-6
1000-12
Range
0.0A -
210.0A
0.0A -
420.0A
0.0A -
105.0A
0.0A -
210.0A
0.00A -
12.60A
0.00A -
25.20A
0.000A -
6.300A
0.00A -
12.60A
Accuracy *12
±(0.5%+0.1A) of
set value
±(0.5%+0.2A) of
set value
±(0.5%+0.05A) of
set value
±(0.5%+0.1A) of
set value
±(0.5%+5mA)
of set value
(
0.5%+10mA
)
of set value
±(0.5%+3mA
)
of set value
±
(
0.5%+6mA
)
of set value
Resolution
0.1A
10mA
1mA
10mA
Load Regulation *10
Below 0.05% + (0.01% of maximum output current)
Below 0.05% + (0.03% of maximum output current)
Line Regulation *5
Below 0.05% + (0.005% of maximum output current)
Ripple (Effective
Value) *6
Below
200mArms
Below
400mArms
Below
100mArms
Below
200mArms
Below
10mArms
Below
20mArms
Below
5mArms
Below
10mArms
Temperature Coefficient
(Typical Value)
±200ppm/
℃
Note: *4: Measurement at sensing point for 0~100% change in rated load current (Static Load Change)
*5: For ± 10% change in input voltage (Static input Change)
*6: At measurement frequency band of 20Hz~1MHz (Resistance Loaded)
*7: Measured with oscilloscope at measurement frequency band of 20Hz~20MHz
*8: Recovery time within 0.1%+10mV of rated output voltage for 50% to 100% abrupt change in rated load current (Dynamic
Load Change)
*9: Time in which set voltage error is reached within 1% due to setting changes via panel operation or communication control or
external analog control.
*10: Current change value at the rated output current when load resistance is changed until resistance value outputs 0~rated
power (Static Load Change)
*11: At output open-circuit and environmental temperature 23
C
± 5
C
*12: At output short-circuit and environmental temperature 23
C
± 5
C
Summary of Contents for HX-S-G4 Series
Page 157: ...Special Loads 157 This page is blank...
Page 161: ...Maintenance 161 This page is blank...
Page 197: ...Specifications 197 External Diagrams 1 HX S 030 200G4 F I...
Page 198: ...Specifications 198 2 HX S 030 400G4 F I...
Page 199: ...Specifications 199 3 HX S 060 100G4 F I...
Page 200: ...Specifications 200 4 HX S 060 200G4 F I...
Page 201: ...Specifications 201 5 HX S 0500 12G4 F I...
Page 202: ...Specifications 202 6 HX S 0500 24G4 F I...
Page 203: ...Specifications 203 7 HX S 01000 6G4 F I...