Basic Usage
26
Default Settings
Factory settings and settings after initialization are as follows:
30V/60V Type
Settings Item
HX030-200
HX030-400
HX060-100
HX060-200
Constant Voltage Set Value
0.00V
0.00V
0.00V
0.00V
Constant Current Set Value
210.0A
420.0A
105.0A
210.0A
Over Voltage Protection
(OVP) Set Value
33.00V
33.00V
66.00V
66.00V
Over Current Protection
(OCP)
220.0A
440.0A
110.0A
220.0A
Settings Values in Memory
A,B,C
Same with the above CV set values, CC set values, OVP set values, OCP set values
Function Settings
See page 33 on Default Values for Function Settings
(excluding section 20~38 Calibration Values)
500V/1000V Type
Settings Item
HX0500-12
HX0500-24
HX01000-6
HX01000-12
Constant Voltage Set Value
0.0V
0.0V
0.0V
0.0V
Constant Current Set Value
12.60A
25.20A
6.300A
12.60A
Over Voltage Protection
(OVP) Set Value
550.0V
550.0V
1100V
1100V
Over Current Protection
(OCP)
13.20A
26.40A
6.600A
13.20A
Settings Values in Memory
A,B,C
Same with the above CV set values, CC set values, OVP set values, OCP set
values
Function Settings
See page 33 on Default Values for Function Settings
(excluding section 20~38 Calibration Values)
Returning Factory Settings
All power supply settings can be initialized.
Step 1: Turn the POWER switch ON while holding down the MEMORY keys “A” and “C”.
Step 2: Release the keys “A” and “C” once the Number Display lights up.
Each setting returns to the factory setting.
Backing-Up Settings
This power supply saves all settings in non-volatile memory (EEPROM) just before the POWER switch is turned
off or immediately before power is cut off.
All previous settings will remain the same when power is turned on again.
* No batteries are used. There is no need to replace batteries.
Summary of Contents for HX-S-G4 Series
Page 157: ...Special Loads 157 This page is blank...
Page 161: ...Maintenance 161 This page is blank...
Page 197: ...Specifications 197 External Diagrams 1 HX S 030 200G4 F I...
Page 198: ...Specifications 198 2 HX S 030 400G4 F I...
Page 199: ...Specifications 199 3 HX S 060 100G4 F I...
Page 200: ...Specifications 200 4 HX S 060 200G4 F I...
Page 201: ...Specifications 201 5 HX S 0500 12G4 F I...
Page 202: ...Specifications 202 6 HX S 0500 24G4 F I...
Page 203: ...Specifications 203 7 HX S 01000 6G4 F I...