Using via Digital Data Communication
97
STATus
:
OUTPut
:
MODE
:
selection of status output function
Function
:
Select status output function.
Same as FUNCTION Setting Item 76.
Format
:
STATus
:
OUTPut
:
MODE[]
<
NR1
>
Type
:
SET command, QUERY command
Parameter
:
0:
LEVEL1_ALM
、 1:
OUTPUT ON/OFF_STS
Response
:
Same as parameters
Restrictions
:
Alarm response is normally returned to set command under the following state.
- Alarm is occurring
- Sequential operation is in progress
- Power supply is operating as slave machine in serial operation
- Power supply is operating as slave machine in parallel operation
<
Ex.
>
STAT
:
OUTP
:
MODE[]0
STAT
:
OUTP
:
MODE?
0