Specifications
193
Protection Functions
Specification/Models
30-200
30-400
60-100
60-200
500-12
500-24
1000-6
1000-12
Over
Voltage
Protection
Circuit
(OVP)
Range
0.30V to 33.00V
0.60V to 66.00V
5.0V to 550.0V
10V to 1100V
Accuracy
± (0.2%
+
5 digit (0.05V)) of
set value * 11
± (0.2%
+
5 digit(0.05V)) of
set value * 11
± (0.2%
+
5 digit (0.5V))
of set value * 11
± (0.2%
+
5 digit (5V)) of set
value * 11
Operation
Can select from operations below
• Output OFF by switching stop
• Input switch cut-off (Input switch cut-off turns the power supply’s internal input power relays OFF.)
Over
Current
Protection
Circuit
(OCP)
Range
2.0A-
220.0A
4.0A-
440.0A
1.0A-
110.0A
2.0A-
220.0A
0.12A-
13.20A
0.24A-
26.40A
0.060A-
6.600A
0.12A-
13.20A
Accuracy
± (0.6%
+
5digit
(0.5A)) of
set value *
12
±
(
0.6
%+
10digit
(
1A
)
of set value
* 11 *12
±
(
0.6
%+
5digit
(
0.5A
))
of set value
* 12
±
(
0.6
%+
10digit
(
1A
))
of set
value * 12
±
(
0.6
%+
5digit
(
50mA
)
of set value *
12
±
(
0.6
%+
10digit
(
100mA
)
of set value
* 12
±
(
0.6
%+
5digit
(
5mA
)
of set value
* 12
±
(
0.6
%+
5digit
(
50mA
)
of set value *
12
Operation
Can select from operations below
• Output OFF by switching stop
•Input switch cut-off (Input switch cut-off turns the power supply’s internal input power relays OFF.)
Over Heating Protection
Circuit
• Stops switching, shuts off output, and displays alarms if the temperature of the radiating section heat
exceeds 90
C due to stopped fan motor, etc.
• Welds temperature fuses, built in the Inrush Limiting Resistors, at 135
C.
Excessive Input Current
Protection
Fuse
35A
Fuse
60A
Fuse
35A
Fuse
60A
Fuse
35A
Fuse
60A
Fuse
35A
Fuse
60A
Remote Sensing
• Able to compensate a voltage drop, due to lead wire up to load, of up to 5V one-way.
• Restricts the rise in output voltage within 10mV if sensing lines are opened.
• During remote sensing, the output power can be set to a maximum of 105% of rated output voltage at
the power supply’s output terminals. Also, the output power can be set within the rating.
Summary of Contents for HX-S-G4 Series
Page 157: ...Special Loads 157 This page is blank...
Page 161: ...Maintenance 161 This page is blank...
Page 197: ...Specifications 197 External Diagrams 1 HX S 030 200G4 F I...
Page 198: ...Specifications 198 2 HX S 030 400G4 F I...
Page 199: ...Specifications 199 3 HX S 060 100G4 F I...
Page 200: ...Specifications 200 4 HX S 060 200G4 F I...
Page 201: ...Specifications 201 5 HX S 0500 12G4 F I...
Page 202: ...Specifications 202 6 HX S 0500 24G4 F I...
Page 203: ...Specifications 203 7 HX S 01000 6G4 F I...