Using via Digital Data Communication
------------------------------------------------------------------------------------
110
SEQuence:MEMB
:Sets Memory B Operating Time
Function:Sets the memory B operating time
Same settings as FUNCTION Settings Item 105~107
Format:SEQuence:MEMB[]※1,※2,※3
Type:SET command, QUERY command
Parameters:※1 0~999(h)
※2 0~59(m)
※3 0.0~59.9(s)
Response:Same as parameters
Restrictions: Alarm response is returned for normal SET commands in the following conditions
・While operating as a series operation slave unit
・While operating as a parallel operation slave unit
・Sequence operation in progress
<Ex.>
SEQ:MEMB[]100,10,10.0
SEQ:MEMB?
100,10,10.0
SEQuence:MEMC
:Sets Memory C Operating Time
Function:Sets the memory C operating time
Same settings as FUNCTION Settings Item 108~110
Format:SEQuence:MEMC[]※1,※2,※3
Type:SET command, QUERY command
Parameters:※1 0~999(h)
※2 0~59(m)
※3 0.0~59.9(s)
Response:Same as parameters
Restrictions: Alarm response is returned for normal SET commands in the following conditions
・While operating as a series operation slave unit
・While operating as a parallel operation slave unit
・Sequence operation in progress
<Ex.>
SEQ:MEMC[]100,10,10.0
SEQ:MEMC?
100,10,10.0
Summary of Contents for ZX-S-1600LAN
Page 1: ...Constant Voltage Constant Current DC Power Supply series Instruction Manual...
Page 13: ...About this Product 10 This is blank page...
Page 63: ...Useful Function 60 This is blank page...
Page 151: ...Controlling with External Analog Contact Signals 148 This is blank page...
Page 157: ...Special Loads 154 This is blank page...
Page 199: ...Specifications 196 This is blank page...
Page 200: ...197 External Diagrams ZX S 400LN 400LAN 4 M3...
Page 201: ...Appendix 198 ZX S 800LN 800LAN...
Page 202: ...Appendix 199 ZX S 1600LN 1600LAN...