129
SERIAL I/F 1
SERIAL I/F 2
TERMINATION
LINE INPUT
OFF
ON
IN
OUT
M/S CONTROL
SENSE
+
DC OUTPUT
-
+ -
3
ツイストペア線
接点
フォトカプラ
または
接点開:出力OFF
接点閉:出力ON
外部接点による、出力のON/OFF
2
M/S CONTROL
(IN)へ
Toggling Output ON/OFF with External Contacts
The output for ZX-S Series power supplies can be toggled ON/OFF using outputs from small
capcity contact or photocoupler.
Use a photocoupler or a small signal relay or switch with a minimum contact capcity of 5V, 2.5mA.
FUNCTION settings must be changed to “Valid” for Output ON/OFF Control at External Contact to be used.
Factory default settings are set to “Invailid”.
Connecting
Wire the cables to connector (XG5M-1432-N or XG5M-1435-N (OMRON)) Pin No. 2 and 3, and connect it to
M/S CONTROL (IN) as shown in the diagram below.
Cable connector
:XG5M-1432-N or XG5M-1435-N(OMRON)
Connector Semi-Cover
:XG5S-0701(OMRON)
Contact
:XG5W-0031-N (for XG5M-1432-N)(OMRON)
XG5W-0034-N (for XG5M-1432-N)( OMRON)
Crimping :XY2B-7006(OMRON)
Extracting Tool
:XY2E-0001(OMRON)
● Not suited for power contact such as main contact points for electromagnetic contactors or
power relays etc.
● For output ON/OFF toggle contact, please use a insulated contact point or open collector.
Caution
1
2
13
14
1
13
2
14
Connector(Socket)
XG5M-1432-N or
XG5M-1435-N(OMRON)
Semi-Cover:XG5S-0701(OMRON)
1
13
2
14
M/S CONTROL(IN) No. 1 terminal is used for factory inspection only.
Please do not use.
Caution
Photocoupler or Contact
Twisted-Pair Wire
To M/S CONTROL
(IN)
Open: Output OFF
Closed: Output ON
Toggling Output ON/OFF at External Contact
Summary of Contents for ZX-S-1600LAN
Page 1: ...Constant Voltage Constant Current DC Power Supply series Instruction Manual...
Page 13: ...About this Product 10 This is blank page...
Page 63: ...Useful Function 60 This is blank page...
Page 151: ...Controlling with External Analog Contact Signals 148 This is blank page...
Page 157: ...Special Loads 154 This is blank page...
Page 199: ...Specifications 196 This is blank page...
Page 200: ...197 External Diagrams ZX S 400LN 400LAN 4 M3...
Page 201: ...Appendix 198 ZX S 800LN 800LAN...
Page 202: ...Appendix 199 ZX S 1600LN 1600LAN...