Basic Operations
------------------------------------------------------------------------------------
21
CC
CV
OUTPUT POWER (%)
STEP
CURRENT
STEP
VOLTAGE
PRESET FUNC. REMOTE LOCK
20
60
100 LMT
40
80
Operating as Constant Current Power Supply
Please verify that the settings for Over Voltage Protection
(OVP) circuit (page 31) and Over Current Protection
(OCP) circuit (page 33) are in effect.
Turn the POWER switch ON to startup the power supply.
The voltage measurement value will display in the top Number
Display, and the current measurement value will display in the
bottom Number Display. Lamp “V” and “A” will light.
(If parameters for FUNCTION settings item 52 is set to 1,
PRESET value will be displayed)
Press the PRESET key.
PRESET lamp will light.
Press the PRESET key again if you wish to discontinue and
return to the measurement display mode.
The voltage limit PRESET value will display in the top Number
Display and the current PRESET value will display in the bottom
Number Display.
Turn the CURRENT dial to adjust the Constant Current
Set Value.
(Turn the dial right to raise or left to lower the set value.)
If the parameter for FUNCTION item 50 is set to 0, press
the PRESET key again. The output voltage will be changed
once PRESET mode has been exited.
If the parameter for FUNCTION item 50 is set to 1, promptly
change the set value using the VOLTAGE dial.
Press the CURRENT dial to display the current number
position. The selected number will be brightened. Press to
change position. If all 4 places are brightened, numbers will
change from the lowest place.
MEMO
OUTPUT
PRESET
OVP
OCP
FUNC.
ALARM RESET
⇒Continued on next page
CC
CV
OUTPUT POWER (%)
STEP
CURRENT
STEP
VOLTAGE
PRESET FUNC. REMOTE LOCK
20
60
100 LMT
40
80
CC
CV
OUTPUT POWER (%)
STEP
CURRENT
STEP
VOLTAGE
PRESET FUNC. REMOTE LOCK
20
60
100 LMT
40
80
When POWER is turned OFF the top and bottom
Number Displays will be displayed in the same
manner when POWER is turned ON again.
MEMO
Summary of Contents for ZX-S-1600LAN
Page 1: ...Constant Voltage Constant Current DC Power Supply series Instruction Manual...
Page 13: ...About this Product 10 This is blank page...
Page 63: ...Useful Function 60 This is blank page...
Page 151: ...Controlling with External Analog Contact Signals 148 This is blank page...
Page 157: ...Special Loads 154 This is blank page...
Page 199: ...Specifications 196 This is blank page...
Page 200: ...197 External Diagrams ZX S 400LN 400LAN 4 M3...
Page 201: ...Appendix 198 ZX S 800LN 800LAN...
Page 202: ...Appendix 199 ZX S 1600LN 1600LAN...