Basic Operations
------------------------------------------------------------------------------------
33
Over Current Protection(OCP) Circuit
In the event of an over current due to a short circuit in the load, the output is turned OFF and switching is
ceased to protect the load.
The OCP current can be set from 1.25% to 125% of the rated current.
Setting/Canceling Over Current Protection
Setting Over Current Protection Level
①.Set the output to OFF with the OUTPUT key.
②.Press the OCP key to display the current OCP set value in
the top Number Display.
③ . Change the set value by turning the VOLTAGE dial while
pressing down the OCP key.
④.Release the OCP key to confirm set values and to return to
measurement display mode.
Verifying Over Current Protection Operation
After settings are complete, please follow the procedures below
to test verify operation.
①.Disconnect the load from the power supply and short between
the +/- output terminals using cross section area wires that
can flow rated current.
②.Turn the POWER switch ON with the Output ON/OFF Toggle
mode set to“0”
③.Set the Output Current settings lower than OCP level.
④.Turn OUTPUT to ON.
⑤.Gradually increase the Output Current with the CURRENT dial.
Verify that the output turns OFF once the OCP set current has
been reached and that the error code "E005" appears in the
top Number Display and "OCP" in the bottom Number Display.
⑥.Hold the OVP and OCP keys simultaneously for more than 1
second to cancel the alarm.
Return the CC set value to its original value.
●
Press the VOLTAGE dial to display the current number
position. The selected number will be brightened. Press to
change positions. If all 4 places are brightened, numbers will
change from the lowest place.
●Press the OCP key to display the set values in the top Number
Display.
●While setting, the CURRENT dial cannot be used.
MEMO
OUTPUT
PRESET
OVP
OCP
POWER
FUNC.
LOCAL
LOCK
DISPLAY
A
B
C
STORE
MEMORY
CC
CV
OUTPUT POWER (%)
STEP
CURRENT
STEP
VOLTAGE
PRESET FUNC. REMOTE LOCK
ALARM RESET
20
60
100 LMT
40
80
ZX-S-400LN
Summary of Contents for ZX-S-1600LAN
Page 1: ...Constant Voltage Constant Current DC Power Supply series Instruction Manual...
Page 13: ...About this Product 10 This is blank page...
Page 63: ...Useful Function 60 This is blank page...
Page 151: ...Controlling with External Analog Contact Signals 148 This is blank page...
Page 157: ...Special Loads 154 This is blank page...
Page 199: ...Specifications 196 This is blank page...
Page 200: ...197 External Diagrams ZX S 400LN 400LAN 4 M3...
Page 201: ...Appendix 198 ZX S 800LN 800LAN...
Page 202: ...Appendix 199 ZX S 1600LN 1600LAN...