Startup Display
Once power is turned on (POWER switch pushed to ON), the power supply model will be displayed in the top Number
Display and the firmware version and number of parallel connected devices will be displayed in the bottom Number
Display.
If there is a disagreement in the number of parallel connected devices (if there is a difference
between the number of parallel devices used previously and now), the error code “E011” will be
displayed in the top Number Display and the number of detected devices will be displayed blinking
in the bottom display. After confirming the number of parallel devices, hold down the FUNC. key
for more 2 seconds to approve and proceed to measurement display mode.
Default Settings
Factory settings and settings after initialization are as followed:
Settings Item
400H/400HA
800H/800HA
1600H/1600HA
Constant Voltage Set Value
0.00V
0.00V
0.0V
Constant Current Set Value
5.250A
10.50A
21.0A
Over Voltage Protection (OVP)
Set Value
704V
704V
704V
Over Current Protection (OCP)
Set Value
5.5A
11.0A
22.0A
Settings Values in Memory
A,B,C
Same with the above CV set values, CC set values, OVP set values, OCP set
values
Function Settings
See page 23 on Default Values for Function Settings (excluding section 20~38
Calibration Values)
POWER
FUNC.
LOCAL
LOCK
ALARM RESET
POWER switch ON
Top Number Display/Displays Model
Bottom Number Display/Displays Fireware Version
Top Number Display/Displays Model
Bottom Number Display/No. of Parallel Devices
Measurement
Display
Models ●ZX-S-400H:
04H
●ZX-S-800H:
08H
●ZX-S-1600H:
16H
Displayed as: ●ZX-S-400HA:
04HA
●ZX-S-800HA:
08HA
●ZX-S-1600HA:
16HA
MEMO
CC
CV
OUTPUT POWER (%)
STEP
CURRENT
STEP
VOLTAGE
PRESET FUNC. REMOTE LOCK
20
60
100 LMT
40
80
CC
CV
OUTPUT POWER (%)
STEP
CURRENT
STEP
VOLTAGE
PRESET FUNC. REMOTE LOCK
20
60
100 LMT
40
80
Summary of Contents for ZX-S-H Series
Page 1: ...Constant Voltage Constant Current DC Power Supply series Instruction Manual ...
Page 37: ...Basic Operations 33 This is blank page ...
Page 59: ...Useful Function 55 This is blank page ...
Page 115: ...Using via Digital Data Communication 111 This is blank page ...
Page 141: ...Controlling with External Analog Contact Signals 137 This is blank page ...
Page 147: ...Special Loads 143 This is blank page 守 ...
Page 188: ... 184 付録 External Diagrams ZX S 400H 400HA 4 M3 ...
Page 189: ...Appendix 185 ZX S 800H 800HA ...
Page 190: ...Appendix 186 ZX S 1600H 1600HA ...