247
OPTIONS
Air Conditioner (TB135 / TB145)
Inspection
1. Tilt up the platform.
2. Press on the center of the belt (1) with a
finger. The belt’s tension is normal if it
bends about 8 mm (0.3 in) when pressed
with a force of about 98N/10 kg (22 lb).
Adjustment
If the belt’s tension is not normal, adjust it
with the adjust bolt (3).
1. Loosen the nut (4).
2. Tighten the bolt (3) to increase the tension.
Loosen the bolt (3) to decrease the tension.
3. After adjusting is completed, tighten the
nut (4).
Replace
Replace the belt in the following cases:
• If it stretches and its tension cannot be
adjusted.
• If it is cut or cracked.
• If the fan belt is worn and the pulley is
touching the bottom of the V groove.
Cleaning the Filter
Clean the filter sooner when operating in
dusty places.
If the filter is clogged, the air becomes weak
and a muted booming sound is heard from
the air conditioner unit.
Removing the filter
1. Loosen the wing bolts (1) and remove the
cover (2).
2. Remove the filter.
3. Use compressed air to clean the filter.
Cleaning
CAUTION
Wear safety glasses when using
compressed air.
1. Blow dry, compressed air (138 kPa or 20
psi or less) directly on the filter from the
inside, moving up and down along the
creases.
Be sure to keep the nozzle at an adequate
distance from the filter.
K3L033
2
1
1
Summary of Contents for TB125
Page 6: ...4 ...
Page 8: ...6 ...
Page 89: ...87 TRANSPORT Loading and Unloading 88 Securing the Machine 89 Cautions on Transporting 90 ...
Page 148: ...146 ...
Page 153: ...151 MEMO ...
Page 166: ...164 MEMO ...
Page 194: ...192 ...
Page 205: ...203 MEMO ...
Page 253: ...251 MEMO ...
Page 258: ...256 ...
Page 259: ...257 INDEX ...