211
OPTIONS
Air Conditioner
INSPECTION AND MAINTENANCE
Inspection and maintenance interval
............................ Every 250 hours
Inspecting and Adjusting the Air
Conditioner Belt
Inspection and maintenance interval
... After first 50 hours (New machines only)
IMPORTANT: Do not let any oil or grease
get on the belt, as it will cause the belt to
slip, shortening its service life and
reducing the air conditioner’s cooling
capacity.
If the belt is slack, it will slip and vibrate,
shortening its service life and reducing the
air conditioner’s cooling capacity. The belt
should also not be too tense. Adjust the belt
tension to the standard value (approximately
8 mm or 0.3 in.).
L3T016
3
2
4
1
2
3
L3T012
4
Inspection
1. Open the engine hood.
2. Press on the center of the belt (1) with a
finger. The belt’s tension is normal if it
bends about 8 mm (0.3 in.) when pressed
with a force of about 98N (22 lbs).
Adjustment
If the belt’s tension is not normal, adjust it
with the adjust bolt (3).
1. Loosen the nut (4).
2. Tighten the bolt (3) to decrease the tension.
Loosen the bolt (3) to increase the tension.
3. After adjusting is completed, tighten the
nut (4).
Replace
Replace the belt in the following cases:
¡
If it stretches and its tension cannot be
adjusted.
¡
If it is cut or cracked.
¡
If the fan belt is worn and the pulley is
touching the bottom of the V groove.
Summary of Contents for TB175
Page 7: ...4...
Page 9: ...6...
Page 157: ...154...
Page 160: ...157 MEMO...
Page 165: ...162 SPECIFICATIONS Operating Range Mono Boom L3K0021 J K H B A E F C D G...
Page 167: ...164 SPECIFICATIONS Operating Range 2 Piece Boom L3L032 J E F G C D K H B A...
Page 169: ...166 MEMO...
Page 183: ...180...
Page 223: ...220...
Page 224: ...221 INDEX...