4 Operation
42
TW9
4.3 Engine
4.3.1 Starting the engine
Each time before putting the machine
into operation, the inspections
according to section 7.8 must be
carried out.
Before switching on the engine, take
care to ensure that no one is in the
immediate vicinity of the machine or in
the danger zone.
•
All gearshift levers to neutral.
•
Parking brake (11/9) applied, travel direction
preselectors (11/8; 11/36) in position "0".
•
Insert ignition key in pre-heat/ starter switch
(11/50).
Hot start
•
Switch on ignition and wait for approx. 5 sec.
The display establishes the internal
readiness for operation. As a result, all
indicator lamps are briefly activated for
a functional check.
•
Turn clockwise to "1"; the indicator lamps
(11/22, 11/31) light up.
•
Pre-heating starts; the indicator lamp (11/21)
lights up.
•
Press the accelerator pedal (11/3) completely
down for normal start and to the quarter-open
position for hot start.
•
After the indicator lamp (11/21) has gone out,
turn the pre-heat/ starter switch to "Start". As
soon as the engine is running, turn the ignition
key to "1" and decrease the revs to low idle
speed. The indicator lamps should go out.
•
If the engine has not started after max.
20 seconds, turn the ignition key to "1" or "0",
and pause for at least 1 minute before trying
again. Repeat the start-up procedure.
Do not drive the engine at full throttle
straight away. Drive with restraint until
the operating temperature of the engine
has been reached.
II
3
36
31
22
21
16
8
50
L1002_011
Fig. 11 Operation
Summary of Contents for TW9
Page 6: ...Table of Contents TW9...
Page 12: ...6 TW9...
Page 42: ...3 Technical data 36 TW9...
Page 46: ...4 Operation 40 TW9 Instrument panel Fig 10 2 Operator controls...
Page 58: ...4 Operation 52 TW9...
Page 112: ...9 Appendix 106 TW9...