background image

Digital indication of sensing information

Simple operation for setting functions

Direct reading of stablility level is
available along with received light level
and displace-ment indications

LCD with backlight for ease of reading

Various convenient functions provided

Full auto/auto teaching

Anti Mutual Interference

Manual sensitivity setting

Off-delay timer

F70A

series

Variation

Simple operation

Simple operation featured

Type

Digital display

general-

purpose type

NPN output

F70AR

F70AG

F70AB

F70AW

PNP output

F70ARPN

F70AGPN

F70ABPN

F70AWPN

Light source

Red LED

Green LED

Blue LED

White LED

Output mode

Open collector

(NPN/PNP)

Model

press

press

press

Received light level and
displacement indications
alternate every time the button
is pressed “once.”

Self-diagnosis
stability indication

Easily viewable color panel

Press “twice” for auto teaching
and hold down for “3 seconds”
for full auto teaching

Press and hold down for “3 seconds”
for switching between operation
modes/light emission frequency
channels for Anti Mutual Interference.

Digital display

Fiber optic sensors

8

Fiber

o

ptic

sensors

Summary of Contents for F71R

Page 1: ...general purpose type NPN output F70AR F70AG F70AB F70AW PNP output F70ARPN F70AGPN F70ABPN F70AWPN Light source Red LED Green LED Blue LED White LED Output mode Open collector NPN PNP Model press pre...

Page 2: ...ctronic volume 8 The level of received light is indicated in 4 digit number Min 0 Max 1023 The example above shows that the current receive light level is 123 with reference to the activation level Le...

Page 3: ...l in high resolution provides highly accurate detection Wide dynamic range and high resolution are achieved at the same time High resolution is maintained even with a wide dynamic range The provided e...

Page 4: ...fluctuates due to dust or water drops Manual hysteresis setting feature The hysteresis can be arbitrarily set according to the application allowing setting of a small hysteresis for severe high accur...

Page 5: ...tion indicator is provided High speed response of 30 s H type sensor Variation Manual high performance model High accuracy 8 turn adjustment is equipped with a position indicator which allows direct r...

Page 6: ...light level Detection output Stability output Stability indicator Flashes Easy to understand stability function When four consecutive detections with a received light level of 120 or lower of the act...

Page 7: ...th straight M8 connector and 2 m cord Model FBC 4R2L equipped with angled M8 connector and 2 m cord Model FA7EU AC BF2 Description DIN rail mounting stopper Amplifier unit mounting bracket End unit Op...

Page 8: ...5 RH non condensing IP40 10 55 Hz 1 5 mm amplitude 2 hours each in 3 direction 500 m s2 3 times each in 3 directions Environment Environmental Specification Specification Light source wavelength Indic...

Reviews: