We appreciate your purchase of a TAKEX passive infrared sensor.  This sensor will provide long and dependable service when properly installed.  
Please read this Instruction Manual carefully for correct and effective use.
Please Note : This sensor is designed to detect intrusion and to initiate an alarm ; it is not a burglary-preventing device. 
                       TAKEX is not responsible for damage, injury or losses caused by accident, theft, Acts of God (including inductive surge by lightning), 
                       abuse, misuse, abnormal usage, faulty installation or improper maintenance.

Caution

 

Plants/Curtain

Refrigerator

Shielding objects

Warning

2

PRECAUTIONS

Be sure to observe

We categorize these precautions throughout the manual using 
the following symbols.

Warning

Caution

An action you must do, and information you should keep in mind

A prohibited action, you must not do.

Facing the window

This manual describes precautions by classifying them based on degrees of danger and 
damage that would be generated if using the unit incorrectly.

This indicates the possibility of severe injury, and 

even death, if ignored or a user handles the unit 

incorrectly.

This indicates the possibility of minor injury and/or 
damage to properties, or of a notification delay in your 
system due to false operations and/or non-detection, if 
ignored or a user handles the unit incorrectly.

Mount the unit on a solid ceiling or wall surfaces 
where reinforcement materials are used. If you 
mount the unit on non-wood materials of plaster 
board or concrete, securely mount it using 
anchors and mounting screws that match the wall 
materials. Unstable mounting may result in injury 
and/or property damage if the unit falls.

Do not disassemble or modify this device. This 
may cause a fire, electrical shock, or malfunction 
of the device.

If the following events occur, turn off the power of 
the unit immediately, and ask the place of 
purchase for repair. Failure to follow this may 
result in fire, electric shock, and/or malfunction.
• Smoke, abnormal odor, and/or sound are found
• Liquid, such as water, and/or foreign material 

has entered the unit

• The unit has deformed and/or damaged parts

Do not apply impact to the unit.
Strong impact may result in performance 
deterioration and/or damage to the unit.

Make sure to perform a sufficient operation 
check on the whole system before operation.

Make sure to check operation when you move 
tables and partitions and change the layout in 
protected rooms.

Refer to the protection area figures, and select 
the installation location. Then, check the actual 
operation, and adjust the appropriate area.

The unit may not operate properly near devices 
that generate a strong electric or magnetic field.
Also, devices near the unit may not operate 
properly due to the magnetic field and/or 
magnetism generated from the unit.
Make sure to confirm before operation.

Avoid installing the unit in the following places. 
Otherwise, non-detection and/or false detection 
may occur.
• Places subject to strong direct or reflected light 

(sunlight,spotlight)

• Places subject to rapid temperature fluctuations 

(air outlets of air-conditioning equipment, etc.)

• Places where moving objects are included in 

the protection area (plants, laundry, etc.)

• Places subject to strong vibration and/or 

electric noise

• Places where pets, such as dogs and cats, 

and/or automatic cleaning robots may pass

• Places where shielding objects (including glass 

and transparent resin, etc.) are included in the 
protection area (shading parts will not be 
detected)

• Places that people can easily touch.

Passive infrared sensors are 
designed to catch changes of 
far-infrared ray energy. 
Energy changes largely when 
the human body moves 
across the protection area, 
which is easy to detect. 
However, energy does not change greatly 
when the human body comes closer in a 
straight line, or stops, which may be difficult to 
detect. In addition, if the protection area 
environment generates similar changes due to 
certain factors, the unit will set off an alarm 
without being able to judge properly.

Do not install the unit in places subject to oil 
smoke or steam, high humidity, and/or a lot of 
dust.Electricity that travels through these 
substances may result in fire, electric shock, 
and/or false operation.

Securely conduct installation work according to 
the instruction manual.
Also, make sure to use the supplied 
accessories and specified components.
Failure to follow this may result in injury and/or 
property damage in the event of fire, electric 
shock or fall of the unit.

This unit is not a waterproof (moisture 
proof/rainproof) or dust-proof structure. Do not 
use the unit in places subject to water and/or 
high humidity, such as bathrooms, and/or 
subject to large amounts of dust or sand. 
Failure to follow this could result in malfunction.

Ask qualified personnel for any electrical work 
necessary for installation, if required. 
Failure to follow this may result in fire and/or 
electric 

shock.

Do not touch terminals with wet hands. Failure to 
follow this may result in electric shock.

Do not connect devices that exceed the indicated 
capacity to the output contact of the unit. Failure 
to follow this may result in electric shock, fire, 
and/or malfunction.

Use the sensor lock to fix the sensor unit for 
operation.  
This can prevent injuries, and/or damage to the 
unit if the unit falls, as well as prevent the sensor 
from being tampered.

Do not use the unit with power voltage levels 
other than those specified. Failure to follow this 
may result in fire, electric shock, and/or 
malfunction.

Do not install this device in a location that cannot 
support its weight. This may cause the device to 
fall and cause an injury or malfunction of the 
device.

This unit is for indoor use. Do not use the unit in 
places subject to water and/or high humidity. 
Failure to follow this may result in malfunction if 
water gets into the unit.

Do not perform aerial wiring of power and signal 
cables. 
Failure to follow this may result in electric shock, 
fire, and/or malfunction.

Do not install the sensor 
directly on the ceiling 
(When installed on ceilling, 
use optional attachment 
BCW-401)