background image

 

 

  Enable  EQ:  check/uncheck  the  checkbox  to  enable/disable  EQ;  used  to  compare 

before-and-after sound effects. [Reset EQ] to set all EQ settings to default zeros. 

 Copy EQ to: copy the EQ settings of the current channel to one of the other three 

channels. 

  Copy  EQ  from:  copy  the  EQ  settings  from one  of  the  other  three  channels  to  the 

current channel. 

 VOL: controls the input volume level of the currently selected channel, range: 0~31. 

 SQ: check/uncheck to enable/disable squelch function which prevents feedback. 

 Echo: check to enable and adjust Echo VOL and Echo delay. Echo VOL: 0~25; Echo 

delay: 22ms~197ms. 

  Excite:  check/uncheck  to  enable/disable  exciter,  which  is  mainly  used  to  beautify 

sound and improve clarity. Odd harmonics: 0~6; Even harmonics: 0~6. 

⑪ 

Master VOL: the master output volume of all four channels, A, B, C, D. 

Note: In this step, we only have to select a corresponding channel and set its priority, 
and  the  other  settings  such  as  EQ,  input/output  volume  can  be  adjusted  later  as 
required  by  live  test  after  syncing  discussion  units.  Close  this  page  to  proceed  to  the 
next step. 
 

5.4.

 

Discussion Unit Management 

Click  [Discussion  Unit  Management]  to  enter  respective  page  where  you  can  manage 
and sync discussion units. 

 

Select [Discussion Unit Management] 

Discussion Unit Management Interface 

 

① Select unit ID: select the ID of

 the unit that requires syncing. 

② Priority: displays the priority level of the currently selected unit

③ Conference mode

: check to enable FIFO (First-In-First-Out) or No DLGT (No Delegate) 

mode. 

④ Register: check/uncheck to enable/disable the selected unit.

 

⑤  Sync  channel  for  selected  unit:  cannot  be  selected  if  the  current 

DU  is 

chairman/guest; subject to receiver channel priority setting. 

⑥ 

Sync: follow below steps for syncing. 

After selecting the Unit ID and Conference mode, power up the DU, and click [Sync] 

to  start  pairing.  At  this  time,  the  indicator  of  the  CU  IR  window  flashes.  Align  the  IR 
windows between the DU and CU until the LED indicator stops flashing and the signal 

Summary of Contents for DG-U100

Page 1: ......

Page 2: ...1 Computer Camera s RS 485 compatible Signal cable s between camera s and control unit the crystal head on the control unit side uses Pins 1 2 6 refer to your camera manual in regards to the camera pi...

Page 3: ...tar DG U100 wireless conference system app Here you will see two login methods a Regular login for regular users see Section 7 usable only after registering the control unit through Password login Not...

Page 4: ...l unit to be configured from the Device list Note A If the drop down list does not show any control unit IP after clicking Search device it is likely that the correct network interface is not chosen a...

Page 5: ...red 5 3 Receiver Channel Management Click Receiver Channel Management to enter the following page Select Receiver Channel Management Channel Management Interface Select CH select any of the four chann...

Page 6: ...ority and the other settings such as EQ input output volume can be adjusted later as required by live test after syncing discussion units Close this page to proceed to the next step 5 4 Discussion Uni...

Page 7: ...or Guest priority will have their channel IDs automatically generated and will be totally occupied By system default the ABCD channel corresponds to Chairman 11 14 or Guest 1 4 C The Register checkbox...

Page 8: ...ot be performed Select unit select the unit that needs to link to a camera Bond to this shows the ID of the camera 1 7 currently linked to the selected unit at If not linked to any is shown instead Se...

Page 9: ...n management software check and enable Tracking and the camera ID the same camera ID set above select the corresponding protocol of the camera the baud rate 9600 software default and then select the u...

Page 10: ...licable only if the priority of the channel is set as Delegate ID displays the ID of the CU selected in Device list under Device Management if you want to monitor other CU in a multi CU system please...

Page 11: ...ce Users can perform regular login by directly clicking the Regular login button or by waiting 30s to be automatically logged in Regular login only provides Floor Control function If the CU is not reg...

Reviews: