Assembly instructions
Maintenance
Version 1.0
Rotary indexer TMF
27 / 35
7.1.2
Checking the oil level
NOTICE
Damage to components
Improper refilling of the lubricant can cause material damage.
•
Before checking the oil level, the rotary indexer must stand still for at least 30 minutes
•
Check the oil level only when the indexer is at a standstill
•
Do not overfill oil. Fill the oil only up to the level of the oil sight glass.
Fig. 15: Checking the oil level
1
Oil drain
2
Oil sight glass
3
Oil fill
The rotary indexer has an oil sight glass and must be checked for correct oil level in accordance with the maintenance plan.
The correct oil level is reached when the oil is in the middle of the oil sight glass (2). Top up oil if necessary.
7.1.3
Oil fill quantities
Gear type
Fill quantity [l]
TMF1000
1.0
TMF2000
4.5
TMF3000
6.0
TMF4000
6.0
TMF5000
14.0
TMF8000
45.0
2
3
1