Assembly instructions
Troubleshooting
32 / 35
Rotary indexer TMF
Version 1.0
8
Troubleshooting
Fault
Possible cause
Remedy
Drive does not turn
•
No supply voltage
•
Drive contactor malfunction
•
Drive protection switch has
triggered
•
Brake not released
•
Incorrectly connected or worn brake
•
Check power supply
•
Change contactor
•
Let the drive cool down; latch the drive
protection switch
The drive turns but the rotary
indexer does not turn and the
roll star / output flange has
no clearance
•
Worm gear malfunction
•
Safety clutch overload / disengaged
•
Input shaft is broken
•
Remove the external blockage /
engage the safety clutch
•
Contact TAKTOMAT GmbH
The drive turns but the rotary
indexer does not turn and the
roll star / output flange has
clearance
•
Cam follower ripped off by large
overload
•
Contact TAKTOMAT GmbH
Drive turns with loud
humming noises
•
Drive operates on 2 phases only
•
Check fuses or drive contactor
•
Measure current in all 3 phases
(voltage measurement is not enough)