Operating Instructions
Model: EV8650
Page 22 of 62
TP05413002 Rev. 03
Copyright © 2009 by Talaris Ltd., Basingstoke (UK)
3.8.1
Value Count Mode Without Size (dEntr and FdEn Modes)
Value without Long or Short edge note detection
Denomination Entry.
(
dEntr
and
FdEn
Modes)
Before placing the notes in the note hopper, press the DENOM key; the current selected
denomination will be displayed.
Whilst the denomination is shown, press the DENOM key repeatedly to scroll through the
pre-defined list of denominations.
Alternatively, whilst the denomination is shown, use the left or right arrow keys to scroll
through the pre-defined list of denominations.
Press the START/STOP key to select that value.
Alternatively, in
dEntr
mode only, the numerical keys may be used to specify any
denomination.
A manually entered denomination must be a multiple of 10 for one of the following values.
Values. 1; 2; 25; 3; 4; 45; 5; 6; 7; 8; 9
With
AUTO
selected the machine will continue to count each bundle at the denomination
set, adding the value of each batch to a running total.
If
AUTO
is not selected the denomination may be changed for each new batch. The
display will show the total value counted.
To clear the running total and to start to count a new denomination press the CLEAR key.
The list of denominations will be specified in a pre-loaded currency table. If there is no
table only dEntr can be used. In this case a default list of denominations will be used:
1; 2; 3; 5; 10; 20; 25; 50; 100; 200; 250; 500; 1000; 2000; 2500; 5000; 10,000; 20,000;
25,000; 50,000
The supervisor can set which denominations are available to the operator.
By default 1; 2; 5; 10; 20; 50; 100; 200; 500
Note: If a note of a different denomination is hidden in a bundle it will be valued as the
denomination selected.
1. Display
7. Speed
2. Total
8. Det
3. Mode
9. Clear
4. Batch
10. Right Arrow
5. Start / Stop
11. Denomination
6. Auto
12. Left Arrow
13. Numeric Keypad
1
2
5
6
7
3
8
4
9
12
10
11
13