Please read the entire instruction manual before operating the Orbital/Microplate 
Shaker.

WArning! do not use the Orbital/Microplate Shaker in a hazardous 
atmosphere or with hazardous materials for which the unit was not designed. 
Also, the user should be aware that the protection provided by the equipment 
may be impaired if used with accessories not provided or recommended by 
the manufacturer, or used in a manner not specified by the manufacturer.
Always operate unit on a level surface for best performance and maximum 
safety.
do not lift unit by the tray.
CAution! To avoid electrical shock, completely cut off power to the unit by 
disconnecting the power cord from the unit or unplug from the wall outlet. 
Disconnect unit from the power supply prior to maintenance and servicing.
Spills should be removed promptly. do not immerse the unit for cleaning.
do not operate the unit if it shows signs of electrical or mechanical damage.

Earth Ground - Protective Conductor Terminal
Alternating Current

Henry Troemner LLC hereby declares under it’s sole responsibility that the 
construction of this product conforms in accordance with the following standards:
Safety standards:
IEC 61010-1 

 Safety requirements for electrical equipment for measurment, 
controland laboratory use. Part I: General Requirements.

IEC 61010-2-010 

 Part II: Particular requirements for laboratory equipment for the 
heating of materials.

IEC 61010-2-051 

 Part II: Particular requirements for laboratory equipment for 
mixing and stirring.

UL Std. No. 61010-1
CSA/CAN C22.2 No. 0-M91
CSA/CAN C22.2 No. 61010-1-04
EMC standards:
FCC-B 

 EN55022-B

EN6100-3-3   EN6100-4-5
EN61000-4-2   EN61000-4-3
EN61000-4-4   EN61000-4-6
EN61000-4-11 

 

EN61326-1 Class A

Associated Eu guidelines:
EMC directive 2004/108/EEC
LVD directive 2006/95/EEC
RoHS directive 2011/65/EU

s

afety

 i

nstruCtions

s

tanDarDs

 & r

egulations

3

Summary of Contents for 1000-3

Page 1: ...Instruction Manual Advanced 1000 3 Orbital Shaker Advanced 1000MP Microplate Shaker...

Page 2: ...___ Supplier ____________________________________________________________ Table of Contents Package Contents 1 Warranty 1 Installation 2 Maintenance Servicing 2 Equipment Disposal 2 Environmental Cond...

Page 3: ...gent or solvent on the front panel which is abrasive or harmful to plastics nor one which is flammable Always ensure the power is disconnected from the unit prior to any cleaning If the unit ever requ...

Page 4: ...immerse the unit for cleaning Do not operate the unit if it shows signs of electrical or mechanical damage Earth Ground Protective Conductor Terminal Alternating Current Henry Troemner LLC hereby dec...

Page 5: ...again be in standby mode B Speed display Displays the speed of the shaker C Up down arrows for set point control On off button starts stops shaking function D The speed indicator light will be illumin...

Page 6: ...mm x 20mm 5 amp quick acting Speed range 100 to 1200rpm Speed accuracy 2 Timer 1 second to 9999 minutes increased in 1 second increments Orbit 0 125 3mm Maximum weight capacity 8lbs 3 6kg up to 1000rp...

Page 7: ...for use with flask media bottle clamps or test tube racks See below for tray configurations Advanced 1000 3 Orbital Shaker Tray Configurations 35 10mL Erlenmeyer Flask Clamps 20 25mL Erlenmeyer Flask...

Page 8: ...ts Fuses 5mm x 20mm 5 amp quick acting Speed range 100 to 1200rpm Speed accuracy 2 Timer 1 second to 9999 minutes increased in 1 second increments Orbit 0 125 3mm Capacity 4 microplates or 2 micro tub...

Page 9: ...1 Place two 2 microplates or deep well blocks diagonally on the tray or place four 4 microplates or deep well blocks on the tray The plates blocks do not have to be filled 2 Place the corner of the p...

Page 10: ...dicate the previous set time b Simultaneously press both the up and down arrows the display will indicate zero 0 00 The unit time is now set to zero 0 00 minutes Alternately you can use the up down ar...

Page 11: ...exceeded loose foot suction cup Press the standby button to clear this error Be sure the load is within the maximum load capacity before restarting the unit If the E04 error persists switch the unit o...

Page 12: ...385703 00 2 Tray 580050 00 3 Display board 380780 00 4 Belt 580019 00 5 Motor 380712 00 6 Motor transition board 380415 00 7 Connection cable 380720 00 8 IEC power entry module 386122 00 9 Feet sucti...

Page 13: ...5702 00 2 Tray assembly 880761 00 3 Display board 380780 00 4 Belt 580019 00 5 Motor 380712 00 6 Motor transition board 380415 00 7 Connection cable 380720 00 8 IEC power entry module 386122 00 9 Feet...

Page 14: ...2 980199 1 5 to 2mL Micro Tube Rack 70 2 980191 Installation of Flask Clamps Orbital Shaker 1 Unit should be in standby mode 2 Remove non skid rubber mat 3 Line up the hole s in the flask clamp to th...

Page 15: ...Universal Harness Platform Part Description Microplate Capacity Capacity Number Universal Harness 2 or 4 1 980192 Installation of 2 Bar Adjustable Platform Orbital Shaker 1 Unit should be in standby...

Page 16: ...201 Wolf Drive PO Box 87 Thorofare NJ 08086 Phone 1 888 TALBOYS Fax 856 686 1601 E mail troemner troemner com www troemner com 715082 00 REV 6 5 15 Manufactured by...

Reviews: