background image

Model

Maximum 

System 

Voltage (V)

Pmax 

(W)

Vmpp 

(V)

Impp 

(A)

Voc 

(V)

Isc 

(A)

Fuse 

Rating 

(A)

TP636P-150; TP636P-150B

1000(IEC)

150

18.0

8.33

22.7

8.78

15

TP636P-145; TP636P-145B

1000(IEC)

145

17.8

8.15

22.5

8.61

TP636P-140; TP636P-140B

1000(IEC)

140

17.7

7.91

22.4

8.43

TP636P-135; TP636P-135B

1000(IEC)

135

17.5

7.71

22.1

8.31

TP636P-130; TP636P-130B

1000(IEC)

130

17.4

7.47

21.9

8.14

TP596M-275; 

1000(IEC)

275

49.4

5.57

60.8

5.90

10

TP596M-270

1000(IEC)

270

49.2

5.49

60.6

5.81

TP596M-265

1000(IEC)

265

48.9

5.41

60.4

5.77

TP596M-260

1000(IEC)

260

48.7

5.32

60.1

5.71

TP596M-255

1000(IEC)

255

48.4

5.27

59.8

5.66

TP596M-250

1000(IEC)

250

47.9

5.21

59.5

5.58

TP596M-245

1000(IEC)

245

47.6

5.13

59.1

5.51

TP596M-240

1000(IEC)

240

47.2

5.09

58.8

5.48

TP596M-235

1000(IEC)

235

46.8

5.02

58.6

5.46

TP596M-230

1000(IEC)

230

46.5

4.95

58.2

5.39

TP572M-210; TP572M-210B

1000(IEC)

210

38

5.53

45.8

5.83

10

TP572M-205; TP572M-205B

1000(IEC)

205

37.9

5.41

45.5

5.79

TP572M-200; TP572M-200B

1000(IEC)

200

37.6

5.32

45.3

5.72

TP572M-195; TP572M-195B

1000(IEC)

195

37.0

5.28

45.1

5.63

TP572M-190; TP572M-190B

1000(IEC)

190

36.5

5.21

45.0

5.56

TP572M-185; TP572M-185B

1000(IEC)

185

35.8

5.17

44.8

5.48

TP572M-180; TP572M-180B

1000(IEC)

180

35.4

5.09

44.6

5.40

TP572M-175; TP572M-175B

1000(IEC)

175

35.3

4.96

44.5

5.34

TP572M-170; TP572M-170B

1000(IEC)

170

35.2

4.83

44.4

5.29

TP536M-105; TP536M-105B

1000(IEC)

105

19.0

5.53

22.8

5.86

10

TP536M-100; TP536M-100B

1000(IEC)

100

18.4

5.43

22.6

5.76

TP536M-95; TP536M-95B

1000(IEC)

95

18.2

5.22

22.5

5.56

TP536M-90; TP536M-90B

1000(IEC)

90

17.7

5.08

22.4

5.38

TP536M-85; TP536M-85B

1000(IEC)

85

17.6

4.83

22.3

5.26

Summary of Contents for TP672M-315

Page 1: ...electing the proper supporting frame 5 3 3 Frame holes mounting 5 4 Electrical mounting 4 1 Module selection 9 4 2 Safety factor 9 4 3 General installation 9 4 4 Grounding 10 5 Commission and maintena...

Page 2: ...allation Information for operators Keep these instructions safe for the entire useful life of the solar installation Please contact your plant supplier for information concerning the formal requiremen...

Page 3: ...can cause arching resulting in grave or mortal injury The severity increases when several modules are connected in series Cover the solar modules with opaque material for the entire duration of assem...

Page 4: ...eners on the modules Use only insulated tools that are approved for work on electrical installations Do not use light concentrators e g mirrors or lenses to attempt to increase the capacity of the mod...

Page 5: ...the assembly substructure That ensures that no mechanical stress e g caused by vibrations twisting or expansion is generated on the module That ensures sufficient back ventilation of the module That...

Page 6: ...le support structures used to support PV modules at correct tilt angles should be wind and snow load rated by appropriate local and civil codes prior to installation Pole mount When installing a modul...

Page 7: ...ponsibility to ensure the clampsused to secure the module sare strong enough The modules are not subject to wind or snow loads exceeding the maximum permissible loads The module clamps which are used...

Page 8: ...edge to 1 4 width of the short frame Use a torque wrench for installation and the compression for each clamps is not strong to avoid potential damages to module frames The recommended maximum compres...

Page 9: ...of the modules and all other system components If modules are connected in series the total voltage is equal to the sum of individual voltages The recom mended max number of module N Vmax system Voc...

Page 10: ...tion The tightening torque is 1 Nm 5 COMMISSION AND MAINTENANCE 5 1 Blocking diodes and bypass diode Blocking diodes prevent current flowing from the battery to the module when no electricity is being...

Page 11: ...Technical data Module Type TP672M TP672M B TP660M TP660M B TP654M TP654M B Power Level 265 315 in increment of 5 215 265 in increment of 5 195 235 in increment of 5 Type 6inch 72cells Multi crystalli...

Page 12: ...255B 1000 IEC 255 30 2 8 44 37 5 8 81 TP660M 250 TP660M 250B 1000 IEC 250 30 1 8 31 37 3 8 78 TP660M 245 TP660M 245B 1000 IEC 245 30 0 8 17 37 2 8 69 TP660M 240 TP660M 240B 1000 IEC 240 29 8 8 06 37...

Page 13: ...IEC 250 30 3 8 25 37 3 8 69 TP660P 245 TP660P 245B 1000 IEC 245 30 1 8 14 37 1 8 65 TP660P 240 TP660P 240B 1000 IEC 240 29 7 8 08 36 9 8 62 TP660P 235 TP660P 235B 1000 IEC 235 29 5 7 97 36 8 8 59 TP66...

Page 14: ...240 47 2 5 09 58 8 5 48 TP596M 235 1000 IEC 235 46 8 5 02 58 6 5 46 TP596M 230 1000 IEC 230 46 5 4 95 58 2 5 39 TP572M 210 TP572M 210B 1000 IEC 210 38 5 53 45 8 5 83 10 TP572M 205 TP572M 205B 1000 IE...

Page 15: ...sales eu talesun com Web www talesun eu com USA Talesun Solar USA 111W Saint John Street Suite 900 San Jose CA 95113 USA Tel 1 800 276 0823 Fax 1 408 645 7111 E Mail sales USA talesun com Web www tal...

Page 16: ...www talesun eu com...

Reviews: